Installing the water heater.

Combustion and Ventilation Air

Ventilation (ambient) air temperature 

must be 100°F or less. Proper operation 

of the water heater requires air for 

combustion and ventilation. Provisions 

for combustion and ventilation air 

must comply with referenced codes and 

standards.
DO NOT block or obstruct any of the 

combustion air inlet openings located 

around the perimeter of the water 

heater.  A minimum of 1” is required 

between these combustion air inlet 

openings and any obstruction.
NOTICE: If the water heater is 

installed in an unconfined space within a 

building of conventional frame, masonry 

or metal construction, infiltration 

air is normally adequate for proper 

combustion and ventilation. If the 

water heater is installed in a confined 

space, provisions for combustion and 

ventilation air must be made.
DO NOT obstruct or block the 

Flammable Vapor Sensor.

A confined space is one having a volume 

of less than 50 cubic feet per 1000 Btuh 

of the aggregate input of all appliances 

within that space. 
The air must be supplied through two 

permanent openings of equal area. One  

is to be located within 12” above the floor 

and the other is to be located within 12” 

from the ceiling.

The minimum net free area of each opening 

must not be less than one square inch 

per 1000 Btuh of the total input rating 

of all the appliances in the enclosure 

(but not less than 100 square inches), if 

each opening communicates with other 

unconfined areas inside the building.
Buildings of unusually tight construction 

shall have the combustion and ventilation 

air supplied from outdoors, or a freely 

ventilated attic or crawl space.
If air is supplied from outdoors, directly or 

through vertical ducts, there must be two 

openings located as specified above and 

each must have a minimum net free area 

of not less than one square inch per 4000 

Btuh of the total input rating of all the 

appliances in the enclosure.
If horizontal ducts are used to 

communicate with the outdoors, each 

opening must have a minimum net free 

area of not less than one square inch per 

2000 Btuh of the total input rating of all 

the appliances in the enclosure. If ducts 

are used, the minimum dimensions of 

rectangular air ducts shall not be less than 

3”.

NOTICE: If the duct openings which 

supply combustion and ventilation air 

are to be covered with a protective 

screen or grill, the net free area 

(openings in the material) of the 

covering material must be used in 

determining the size of the openings. 

Protective screening for the openings 

MUST NOT be smaller than 1/4”mesh 

to prevent clogging by lint or other 

debris.

Corrosive Atmospheres

The air in beauty shops, dry cleaning 

establishments, photo processing 

labs,  and storage areas for liquid and 

powdered bleaches or swimming pool 

chemicals often contain such halogenated 

hydrocarbons.
An air supply containing halogenated 

hydrocarbons may be safe to breathe,  

but when it passes through a gas flame 

corrosive elements are released that  

will shorten the life of any gas burning 

appliance.
Propellants from common spray cans 

or gas leaks from A/C and refrigeration 

equipment are highly corrosive after 

passing through a flame.
The water heater warranty is voided when 

failure of the heater is due to operation in 

a corrosive atmosphere.

NOTICE: The water heater 

should not be installed near 

an air supply containing 

halogenated hydrocarbons.

 

Inspect Shipment

Inspect the water heater for possible damage. Check the markings on the rating plate of 

the water heater to be certain the type of gas supplied corresponds to the water heater 

requirements.

NOTICE:  Do not install the 

water heater in attics where 

the temperature may exceed 

100°F.  This water heater is 

equipped with a temperature 

sensing device that will 

shut off the water heater 

if the maximum allowable 

vent pipe temperature is 

exceeded.

Содержание PowerVent AP14236

Страница 1: ...he basic directions and recommendations for the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precautions maintenance a...

Страница 2: ...time and money over the life of your water heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to ca...

Страница 3: ...s paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a water hea...

Страница 4: ...rature Dial D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual...

Страница 5: ...LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look...

Страница 6: ...installation For residential water heaters of a capacity greater than 52 gallons consult the local building jurisdiction for acceptable bracing procedures Have the installer show you the location of t...

Страница 7: ...ate a shut down condition of the water heater which will not allow the water heater to ignite until examined by a Qualified Service Technician The water heater must be located so it is not subject to...

Страница 8: ...than one square inch per 4000 Btuh of the total input rating of all the appliances in the enclosure If horizontal ducts are used to communicate with the outdoors each opening must have a minimum net...

Страница 9: ...ondition and eliminating the repeated operation of the relief valve Other methods of controlling thermal expansion are also available Contact your installing contractor water supplier or plumbing insp...

Страница 10: ...ncealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To Fill the Water Heater Make certain that the drain valve...

Страница 11: ...s supply piping at pressures equal to or less than 3 8 psi 10 5 w c for natural gas or 1 2 psi 14 w c for LP gas Gas Supply The branch gas supply line to the water heater should be clean 1 2 black ste...

Страница 12: ...nual have been met Carefully inspect the entire venting system for any signs of cracks or fractures particularly at the joints between elbows or other fittings and the straight length of vent pipe Che...

Страница 13: ...s For the 2 vent one 90 elbow is approximately equal to 6 feet of vent pipe One 45 elbow is approximately equal to 3 feet of vent pipe Minimum vent length for 2 vent pipe is one 1 foot of vertical pip...

Страница 14: ...t Pipe Length in Feet ft 0 Maximum Altitude See chart on upper left One 1 None 95 One 1 One 1 92 5 Two 2 None 90 Two 2 One 1 87 5 Three 3 None 85 Three 3 One 1 82 5 Four 4 None 80 Four 4 One 1 77 5 Fi...

Страница 15: ...xterior wall under the eaves and on surrounding objects Some discoloration to the exterior of the building is to be expected However improper location or installation can result in severe damage to th...

Страница 16: ...without additional support for vent Four 4 feet from any gable dormer or other roof structure with building interior access i e vent window etc Ten 10 feet from any forced air inlet to the building A...

Страница 17: ...the joint with a rag Allow 15 minutes before handling Cure time will vary according to fit temperature and humidity NOTICE Stir the solvent cement frequently while using Use a natural bristle brush or...

Страница 18: ...nce with latest edition of the National Electric Code ANSI NFPA No 70 Refer to the figures below for water heater internal wiring NOTE It is not recommended that this unit be installed on a GFCI circu...

Страница 19: ...ication of an external insulation blanket to this water heater pay careful attention to the following so as not to restrict the proper function and operation of the water heater Do not cover the opera...

Страница 20: ...cess Door unless absolutely necessary This should only be done by a qualified service technician A new burner access door gasket must be installed on any burner access door that has been removed DON T...

Страница 21: ...and free of leaks Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to check all connections and fittings for possible gas l...

Страница 22: ...ating Installation Spring loaded check valve in heating unit hot water supply line and cold water return line not supplied with water heater NOTE This check valve is incorporated in some heating units...

Страница 23: ...s phone Follow the gas suppliers Do not try to light any appliance Do not touch any electric switch do not use any phone in your building WHAT TO DO IF YOU SMELL GAS 9 10 Stop Read the safety informa...

Страница 24: ...temperature of the water in the water heater can be regulated by pressing the buttons on the front of the gas control thermostat Safety and energy conservation are factors to be considered when selec...

Страница 25: ...refore always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury Also always supervise young children or others who are...

Страница 26: ...as valve which will extinguish the main burner flames The blower motor will stay energized for an additional 30 seconds after the control verifies that the burner flame is extinguished in order to cle...

Страница 27: ...ef valve on the water heater discharges periodically this may be due to thermal expansion in a closed water system Contact the water supplier or your plumbing contractor on how to correct this DO NOT...

Страница 28: ...ealed area If the burner access door is removed the burner access door gasket must be replaced For cleaning remove the burner from the water heater A vacuum cleaner can be used on the burner and floor...

Страница 29: ...Gas Caution in the Operating Instructions Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glass lined tank The anode rod is slowly consumed thereby elimin...

Страница 30: ...inlet openings on water heater jacket Not enough combustion or Proper operation of the water heater requires air for ventilation air supplied to combustion and ventilation See the Combustion and the...

Страница 31: ...ion Shutoff System Contact a qualified service technician tripped Water is too hot The gas control thermostat See the Water Temperature Setting of The Water is set too high Heater section of this manu...

Страница 32: ...d A B C Error in the hot surface ignitor cir cuit 1 Check that all wiring is correct and secure 2 Replace hot surface ignitor A B C System in lockout 1 Gas supply is off or too low to operate 2 Hot su...

Страница 33: ...hermostat burners vent connectors or other safety devices Refer repairs to qualified service personnel Use only original equipment replacement parts Blower Assembly Flue baffle and hanger Anode rod He...

Страница 34: ...34 Notes...

Страница 35: ...35 Notes...

Страница 36: ...an attic the hard wired carbon monoxide detec tor with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requirements of this subdivision can not be...

Отзывы: