IF YOU NEED SERVICE

1.  Should you have any questions about your new water heater, or if it requires adjustment, repair, or routine 

maintenance, it is suggested that you first contact your installer, plumbing contractor or previously agreed upon service 

agency. In the event the firm has moved, or is unavailable, refer to the telephone directory, commercial listings or local 

utility for qualified service assistance.
2.  Should your problem not be solved to your complete satisfaction, you should then contact the Manufacturer’s National 

Service Department at the following address: 

    

 

 

2600 Gunter Park Drive East

    

 

 

Montgomery, Alabama 36109-1413

    

 

 

Phone: 1-800-432-8373. 

  When contacting the manufacturer, the following information will be requested:

a.  Model and serial number of the water heater as shown on the rating plate attached to the jacket of the heater.

b.  Address where the water heater is located and physical location.

c.  Name and address of installer and any service agency who performed service on the water heater.

d.  Date of original installation and dates any service work was performed.

e.  Details of the problems as you can best describe them.

f.  List of people, with dates, who have been contacted regarding your problem.

The Commonwealth of Massachusetts requires compliance with regula-

tion 

5.08: Modifications to NFPA-54, Chapter 10 : 

248 CMR 4.00 

and 5.00 for installation of through – the – wall vented gas appliances as 

follows:

(1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as fol-

lows:

Existing chimneys shall be permitted to have their use continued when a gas 

conversion burner is installed, and shall be equipped with a manually reset 

device that will automatically shut off the gas to the burner in the event of a 

sustained back-draft.

(2) Revise 10.8.3 by adding the following additional requirements:

(a) For all side wall horizontally vented gas fueled equipment installed in 

every dwelling, building or structure used in whole or in part for residential 

purposes, including those owned or operated by the Commonwealth and 

where the side wall exhaust vent termination is less than seven (7) feet above 

finished grade in the area of the venting, including but not limited to decks 

and porches, the following requirements shall be satisfied: 

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time 

of installation of the side wall horizontal vented gas fueled equipment, the 

installing plumber or gasfitter shall observe that a hard wired carbon monox

-

ide detector with an alarm and battery back-up is installed on the floor level 

where the gas equipment is to be installed. In addition, the installing plumber 

or gasfitter shall observe that a battery operated or hard wired carbon mon

-

oxide detector with an alarm is installed on each additional level of the dwell-

ing, building or structure served by the side wall horizontal vented gas fueled 

equipment. It shall be the responsibility of the property owner to secure the 

services of qualified licensed professionals for the installation of hard wired 

carbon monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is 

installed in a crawl space or an attic, the hard wired carbon monoxide detec-

tor with alarm and battery back-up may be installed on the next adjacent floor 

level.

b. In the event that the requirements of this subdivision can not be met at the 

time of completion of installation, the owner shall have a period of thirty (30) 

days to comply with the above requirements; provided, however, that during 

said thirty (30) day period, a battery operated carbon monoxide detector with 

an alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon 

monoxide detector as required in accordance with the above provisions shall 

comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 

3. SIGNAGE. A metal or plastic identification plate shall be permanently 

mounted to the exterior of the building at a minimum height of eight (8) feet 

above grade directly in line with the exhaust vent terminal for the horizon-

tally vented gas fueled heating appliance or equipment. The sign shall read, 

in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY 

BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS".

4. INSPECTION. The state or local gas inspector of the side wall horizon-

tally vented gas fueled equipment shall not approve the installation unless, 

upon inspection, the inspector observes carbon monoxide detectors and 

signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 

through 4. 

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 

5.08(2)(a)1 through 4: 

1. The equipment listed in Chapter 10 entitled "Equipment Not Required To 

Be Vented" in the most current edition of NFPA 54 as adopted by the Board; 

and 

2. Product Approved side wall horizontally vented gas fueled equipment in-

stalled in a room or structure separate from the dwelling, building or structure 

used in whole or in part for residential purposes. 

(c) MANUFACTURER REqUIREMENTS - GAS EqUIPMENT VENTING 

SYSTEM PROVIDED. When the manufacturer of Product Approved side 

wall horizontally vented gas equipment provides a venting system design or 

venting system components with the equipment, the instructions provided 

by the manufacturer for installation of the equipment and the venting system 

shall include:

1. Detailed instructions for the installation of the venting system design or 

the venting system components; and

2. A complete parts list for the venting system design or venting system. 

(d) MANUFACTURER REqUIREMENTS - GAS EqUIPMENT VENTING 

SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved 

side wall horizontally vented gas fueled equipment does not provide the parts 

for venting the flue gases, but identifies "special venting systems", the fol

-

lowing requirements shall be satisfied by the manufacturer:

1. The referenced "special venting system" instructions shall be included with 

the appliance or equipment installation instructions; and 

2. The "special venting systems" shall be Product Approved by the Board, 

and the instructions for that system shall include a parts list and detailed 

installation instructions. 

(e) A copy of all installation instructions for all Product Approved side wall 

horizontally vented gas fueled equipment, all venting instructions, all parts 

lists for venting instructions, and/or all venting design instructions shall 

remain with the appliance or equipment at the completion of the installation. 

Important Instructions for the Commonwealth of Massachusetts

Содержание PowerVent AP14236

Страница 1: ...he basic directions and recommendations for the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precautions maintenance a...

Страница 2: ...time and money over the life of your water heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to ca...

Страница 3: ...s paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a water hea...

Страница 4: ...rature Dial D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual...

Страница 5: ...LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look...

Страница 6: ...installation For residential water heaters of a capacity greater than 52 gallons consult the local building jurisdiction for acceptable bracing procedures Have the installer show you the location of t...

Страница 7: ...ate a shut down condition of the water heater which will not allow the water heater to ignite until examined by a Qualified Service Technician The water heater must be located so it is not subject to...

Страница 8: ...than one square inch per 4000 Btuh of the total input rating of all the appliances in the enclosure If horizontal ducts are used to communicate with the outdoors each opening must have a minimum net...

Страница 9: ...ondition and eliminating the repeated operation of the relief valve Other methods of controlling thermal expansion are also available Contact your installing contractor water supplier or plumbing insp...

Страница 10: ...ncealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To Fill the Water Heater Make certain that the drain valve...

Страница 11: ...s supply piping at pressures equal to or less than 3 8 psi 10 5 w c for natural gas or 1 2 psi 14 w c for LP gas Gas Supply The branch gas supply line to the water heater should be clean 1 2 black ste...

Страница 12: ...nual have been met Carefully inspect the entire venting system for any signs of cracks or fractures particularly at the joints between elbows or other fittings and the straight length of vent pipe Che...

Страница 13: ...s For the 2 vent one 90 elbow is approximately equal to 6 feet of vent pipe One 45 elbow is approximately equal to 3 feet of vent pipe Minimum vent length for 2 vent pipe is one 1 foot of vertical pip...

Страница 14: ...t Pipe Length in Feet ft 0 Maximum Altitude See chart on upper left One 1 None 95 One 1 One 1 92 5 Two 2 None 90 Two 2 One 1 87 5 Three 3 None 85 Three 3 One 1 82 5 Four 4 None 80 Four 4 One 1 77 5 Fi...

Страница 15: ...xterior wall under the eaves and on surrounding objects Some discoloration to the exterior of the building is to be expected However improper location or installation can result in severe damage to th...

Страница 16: ...without additional support for vent Four 4 feet from any gable dormer or other roof structure with building interior access i e vent window etc Ten 10 feet from any forced air inlet to the building A...

Страница 17: ...the joint with a rag Allow 15 minutes before handling Cure time will vary according to fit temperature and humidity NOTICE Stir the solvent cement frequently while using Use a natural bristle brush or...

Страница 18: ...nce with latest edition of the National Electric Code ANSI NFPA No 70 Refer to the figures below for water heater internal wiring NOTE It is not recommended that this unit be installed on a GFCI circu...

Страница 19: ...ication of an external insulation blanket to this water heater pay careful attention to the following so as not to restrict the proper function and operation of the water heater Do not cover the opera...

Страница 20: ...cess Door unless absolutely necessary This should only be done by a qualified service technician A new burner access door gasket must be installed on any burner access door that has been removed DON T...

Страница 21: ...and free of leaks Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to check all connections and fittings for possible gas l...

Страница 22: ...ating Installation Spring loaded check valve in heating unit hot water supply line and cold water return line not supplied with water heater NOTE This check valve is incorporated in some heating units...

Страница 23: ...s phone Follow the gas suppliers Do not try to light any appliance Do not touch any electric switch do not use any phone in your building WHAT TO DO IF YOU SMELL GAS 9 10 Stop Read the safety informa...

Страница 24: ...temperature of the water in the water heater can be regulated by pressing the buttons on the front of the gas control thermostat Safety and energy conservation are factors to be considered when selec...

Страница 25: ...refore always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury Also always supervise young children or others who are...

Страница 26: ...as valve which will extinguish the main burner flames The blower motor will stay energized for an additional 30 seconds after the control verifies that the burner flame is extinguished in order to cle...

Страница 27: ...ef valve on the water heater discharges periodically this may be due to thermal expansion in a closed water system Contact the water supplier or your plumbing contractor on how to correct this DO NOT...

Страница 28: ...ealed area If the burner access door is removed the burner access door gasket must be replaced For cleaning remove the burner from the water heater A vacuum cleaner can be used on the burner and floor...

Страница 29: ...Gas Caution in the Operating Instructions Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glass lined tank The anode rod is slowly consumed thereby elimin...

Страница 30: ...inlet openings on water heater jacket Not enough combustion or Proper operation of the water heater requires air for ventilation air supplied to combustion and ventilation See the Combustion and the...

Страница 31: ...ion Shutoff System Contact a qualified service technician tripped Water is too hot The gas control thermostat See the Water Temperature Setting of The Water is set too high Heater section of this manu...

Страница 32: ...d A B C Error in the hot surface ignitor cir cuit 1 Check that all wiring is correct and secure 2 Replace hot surface ignitor A B C System in lockout 1 Gas supply is off or too low to operate 2 Hot su...

Страница 33: ...hermostat burners vent connectors or other safety devices Refer repairs to qualified service personnel Use only original equipment replacement parts Blower Assembly Flue baffle and hanger Anode rod He...

Страница 34: ...34 Notes...

Страница 35: ...35 Notes...

Страница 36: ...an attic the hard wired carbon monoxide detec tor with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requirements of this subdivision can not be...