background image

16

Impulse Time

Code Number

The four digit code number 

can be set in the menu set-

tings (“6”) . In delivery state 

the code number “0000” 

is set . If the code number 

“1111” is set, the testing of 

the code number is left out 

(see page 29) . The default 

settings can be restored by 

a procedure (see page 8) if 

you have forgotten your code 

number .

The connection will be re-

leased, after entering the 

wrong code number three 

times . 

The number of ringing sig-

nals until answering an in-

coming call by the TC easy 

Plus can be set in the menu 

settings (“5”) . The default 

setting is “2” . 

If the answering machine 

mode is activated, the set-

ting of the number of ringing 

signals does not have any 

meaning .

Ringing Signals

Operation

With the impulse time the 

outputs can be activated for 

a pre-determined time . For 

instance, a door opener can 

be activated for a short time 

or a pump can be turned on 

for several hours . The se-

lected impulse time (“7”, “8” 

or “9” in menu settings) is 

valid for all outputs . The im-

pulse time can be selected 

from 1 second and up to 24 

hours . In delivery state the 

impulse time is set to 3 sec-

onds .

Содержание TC Easy Plus

Страница 1: ...TC easy Plus Operating instructions ...

Страница 2: ...all acceptance 4 pushbutton automatic call acceptance Accessory Plug power supply 12 V Operating instructions optional Temperature sensor 700 802 201 Emergency power supply NV 2 TC GB 700 900 139 Additional module SAR 2 Ap GB 500 101 05 4 3 1 2 Overview 2 ...

Страница 3: ...Factory Settings 8 Connection of Telephone Line Plug Power Supply Inputs and Temperature Sensor 9 Connection of Outputs and Pushbuttons 10 Operation State Request 12 General Settings 13 Menu Settings 14 Alarm Phone Numbers 14 Own Phone Number 15 Answering Machine Mode 15 Table of Contents 3 ...

Страница 4: ...Procedures 18 Switch Devices and Impulse Time Check the State of Devices and Temperatures 25 Alarm Messages 27 Unprotected Mode 29 Time out 29 Power Supply 29 Behavior at Power Failure 30 Technical Data 31 Current Consumption 33 Guarantee 34 Service 34 Manufacturer s Declaration 35 ...

Страница 5: ...uncements The temperature can be ac quired via the telephone if a temperature sensor is con nected to an analogue input An alarm call can be initiated if a temperature level is set Two of the five switching outputs are equipped with relays for the connection of devices with low voltage up to 48 V AC DC The remai ning three outputs deliver a control voltage of 12 V 150 mA for relays i e SAR 2 GB 50...

Страница 6: ...e printed circuit board must show to the bottom Slotted holes allow an exact ad justment see figure A 2 There are performed re ceptacles for holding i e the strain relief of the plug power supply cord see figure B 3 Lead the necessary in stallation cables for the devices A1 to A5 through the other entry points of Installation Wall Mounting the base plate see fig ure C ...

Страница 7: ...wire of the plug power supply with and the red black wire with 12V see page 9 If the wires are cross connected the de vice will not be damaged but simply will not oper ate 3 The wiring for the de vices must carried out ac cording to the diagram on page 10 4 Install the equipment to be switched respectively the control relays as shown in the connection diagramm an page 10 5 Insert the plug power su...

Страница 8: ...hone number 1 none Alarm phone number 2 none Own phone number none Answering machine mode off Ringing signals 2 Code number 0000 Impulse time 3 sec Temperature level none Own Settings _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

Страница 9: ...9 Installation Connection of Telephone Line Plug Power Supply Inputs and Temperature Sensor ...

Страница 10: ...10 Connection of Outputs and Pushbuttons Installation ...

Страница 11: ...hbuttons for local operation are con nected electrically parallel to the integrated pushbut tons S1 to S5 The outputs A1 and A2 have relay con tacts with a load capacity of 48 V 2 A AC DC The out puts A3 to A5 can deliver 12 V 150 mA ...

Страница 12: ... The as signed LED lights up The device seizes the telephone line after reception of the programmed number of ring ing signals see page 16 and 21 The LED starts blinking after receiving the first ringing signal With the pushbuttons S1 to S5 devices connected to the output can be switched on or off The as signed LEDs S1to S5 indi cates the switching state LED lit on Operation Call the TC easy Plus ...

Страница 13: ...13 Operation Call the TC easy Plus and dial the code number Please dial a digit setting digit 9 menu settings disconnection settings announcement With disconnection without announcement General Settings ...

Страница 14: ...ephone and DTMF in the menu settings 1 respectively 2 Alarm Phone Numbers 9 impulse time in hours announcement of menu item input of value 1 24 digits number confirmation Confirmation of input abort of input announcement of value input or menu settings announcement Operation Menu Settings Call the TC easy Plus and dial the code number and the digit 9 for the selection of the menu settings menu ite...

Страница 15: ...e in the menu settings 4 If the answering machine mode has been activated the base module will not switch on at an incoming call If the caller releases the telephone line after one ringing sig nal waits at least 10 sec onds and calls again within 60 seconds the base mod ule switches on after the first ringing signal Answering Machine Mode If the TC easy Plus sends off an alarm message via the tele...

Страница 16: ... until answering an in coming call by the TC easy Plus can be set in the menu settings 5 The default setting is 2 If the answering machine mode is activated the set ting of the number of ringing signals does not have any meaning Ringing Signals Operation With the impulse time the outputs can be activated for a pre determined time For instance a door opener can be activated for a short time or a pu...

Страница 17: ...n be done in a way that the exceed ing more than or the falling short less than of a cer tain temperature will send off an alarm call Negative val ues can be set by placing a 9 before entering the tem Operation perature level The adjusta ble range comprises temper atures from 9 C to 40 C The TC easy Plus has a hys teresis of 3 C that means if for instance a temperature level of more than 25 C has ...

Страница 18: ...rom a telephone After en tering the code number the menu settings can be se lected by dialing the digit 9 The menu will start with the following announcement described as setting an nouncement in the exam ples Settings To set the alarm phone numbers press 1 for input 1 and press 2 for input 2 To set the own phone number press 3 To set the answering ma chine mode press 4 To set Operation An overvie...

Страница 19: ...number 1 Here is the TC easy Plus Please dial the code num ber Please dial a digit setting announcement Phone number one Please dial For confirmation press the pound key for cancalla tion the asterisk key Phone number one 4711 Phone number of the TC easy Plus line 0000 9 1 4711 Setting Procedures ...

Страница 20: ...al For confirmation press the pound key for cancella tion press the asterisk key Phone number two 0815 setting announcement Own phone number Please dial For confirmation press the pound key for cancella tion press the asterisk key Own phone number 0235582224 2 0815 3 0235582224 Setting Procedures ...

Страница 21: ... announcement Answering machine mode Please dial Answering ma chine mode on 1 Answer ing machine mode off 0 For confirmation press the pound key for cancellation press the asterisk key Answering machine mode off setting announcement Ringing signals 2 Please dial For confirmation press 4 5 Setting Procedures ...

Страница 22: ...sterisk key Ringing signals 7 setting announcement Code number 0000 Please dial New code number For confirmation press the pound key for cancellation press the asterisk key New code number 1873 setting announcement Setting of code number Setting Procedures ...

Страница 23: ...f temperature level Impulse mode 3 seconds Please dial Seconds For confirmation press the pound key for cancellation press the asterisk key Impulse mode 35 seconds setting announcement Temperature level off Please dial More than 1 Less than 2 For confirma tion press the pound key for cancellation press the aster isk key Setting Procedures ...

Страница 24: ...nection Please dial temperature level For confirmation press the pound key for cancella tion press the asterisk key Temperature level more than 28 degrees setting announcement Please dial a digit 1 28 1 Setting Procedures 1 For negative values the first digit must be a 9 ...

Страница 25: ...ce 5 is turned on Impulse mode 35 seconds Please dial a digit The temperature is 22 de grees Please dial a digit Call the phone number of the TC easy Plus 1873 51 56 6 Turning on device 5 Turning on device 5 for the programmed time Checking the temperature Switch Devices and Impulse Time Check the State of Devices and Temperatures ...

Страница 26: ...ing the state of device 5 Release connection 2 5 Switch Devices and Impulse Time Check the State of Devices and Temperatures The device 2 is turned off Please dial a digit The device 5 is turned on Impulse mode 35 seconds Please dial a digit ...

Страница 27: ...alarm has been con firmed Please dial the code number Input 2 has been activated TC easy Plus dials the pro grammed alarm phone num ber The alarm will not be con firmed After a 2 min break the alarm phone number 2 will be called again The alarm has been con firmed Alarm Messages The TC easy Plus will send off a maximum of 2 dialing attempts ...

Страница 28: ... TC easy Plus calls the alarm phone number 1 The alarm has been con firmed Release connection or enter the code number for switch ing on or off devices Here is the TC easy Plus 0235582224 The temper ature level is more than 25 degrees The temperature is 27 degrees The alarm has been con firmed Please dial the code number 4711 Alarm Messages ...

Страница 29: ...o DTMF signals have been received for 60 seconds the device will release the tele phone line Special Features If the code number 1111 is set the testing of the code number will be left out which means directly after seizing the telephone line switching functions and menu settings can be performed Power Supply Time out Unprotected Mode ...

Страница 30: ...ower failure If a power failure takes place during an alarm call the alarm call will be re peated after the power re turns Hint Should a power failure occur during an impulse operation of an output the appropriate output will remain switched off after the power returns Special Features Behavior at Power Failure ...

Страница 31: ...y Telephone connection Plug power supply Input voltage Technical Data 143 x 81 x 28 mm 400 g pure white according to RAL 9010 5 to 45 C 25 to 70 C IP30 according to EN 60529 12 V DC with screw terminals potential free contact max 48 V 2 A AC DC control voltage 12 V 150 mA for potential free contacts Schaltdauer 50 ms see table on page 33 20 Hz to 60 Hz analogue connection according to CTR 21 12 V ...

Страница 32: ... values 10 C 25 C 40 C B value II 700 802 201 600 mm to approx 10 m 10 C to 40 C resolution 1 C 42 4 k 10 k 5 8 k 3435 K 1 Subjected to technical changes Technical Data All inputs and outputs are exclusively designed for the connection of electrical cir cuits with SELV according to DIN VDE 0100 410 ...

Страница 33: ...g state Power consumption at supply voltage of 12 V Idle state call acceptance on Connection state no announcement during announce ment all relays off 28 mA 45 mA 57 mA one relay on 45 mA 60 mA 74 mA two relays on 62 mA 77 mA 92 mA ...

Страница 34: ...nction to Rutenbeck Service Center Gewerbegebiet Im Meilesfelde 5 99819 Marksuhl GERMANY Phone 49 36925 90091 Fax 49 36925 90092 We guarantee the perfect function of the TC easy Plus and TC Z easy for 2 years after date of purchase re ceipt providing that it was professionally installed and operated Service Guarantee ...

Страница 35: ...ce system accord ing to Annex V of directive 1999 5 EC certified by Noti fied Body No 0682 and that the mentioned equipment is in compliance with the es sential requirements and provisions of the directive 1999 5 EC The complete declaration of conformity can be found under www rutenbeck de in the download sector Manufacturer s Declaration ...

Страница 36: ...Niederworth 1 10 58579 Schalksmühle GERMANY Phone 49 2355 82 0 Telefax 49 2355 82 105 www rutenbeck de mail rutenbeck de Wilhelm Rutenbeck GmbH Co KG 2007 293 553 Status 02 12 ...

Отзывы: