Die unten abgebildete Bohrschablone gilt für das 

Patchpanel PP-UM A 6 Ap.

Der Abstand beim Patchpanel PP-UM A 12 Ap 

beträgt stattdessen 222 mm.

The drilling template shown below is for the 

PP-UM A 6 Ap patch panel.

The distance between the holes for the PP-UM A 

12 Ap patch panel is 222 mm.

Bohrschablone 

Drilling template 

113 mm

5

Содержание PP-UM A 6 Ap

Страница 1: ...e patch panel offers enough space for the sim ple installation of a maximum of 6 UM Cat univer sal modules or KMK communication adapters and is made of a stable fully shielded metal housing It also contains the ground connection straps for fastening the cables and recesses in the housing for wall mounting Modules can also be added at any time after installation The housing is suitable for wall mou...

Страница 2: ... das konfektionierte Modul von hinten heran Haken Sie das Modul mit der Rastnase D Choose the installation location so that the function of the patch panel will not be impaired by splashing water for example Make sure to select a patch cable with a connector designed according to stand ards i e according to IEC 60603 7 x to ensure trouble free operation Mounting the housing Remove the housing cove...

Страница 3: ...rwendung nicht normgerechter Anschluss komponenten müssen wir von einer Anerkennung the face plate of the base and push down to click it in place Fastening the cables Take the length of the data cables into account when choosing the final installation location Fas ten each cable in place separately using cable ties E for example Removing modules Insert the screwdriver from the bottom in the mid dl...

Страница 4: ...en darf sondern in dafür ausgerüsteten Sammelzentren zur sachgemäßen Wiederverwendung bzw Entsorgung abzugeben ist if connector components not conforming to the standards are used Please inform the end users of this fact You should also avoid unnecessary mechanical strain on the jacks when plugging or unplugging patch cables due to pulling or pressing on the connector or inserting them incorrectly...

Страница 5: ...UM A 6 Ap Der Abstand beim Patchpanel PP UM A 12 Ap beträgt stattdessen 222 mm The drilling template shown below is for the PP UM A 6 Ap patch panel The distance between the holes for the PP UM A 12 Ap patch panel is 222 mm Bohrschablone Drilling template 113 mm 5 ...

Страница 6: ...ungssystems hergestellt wurde und sich in Übereinstimmung mit den Anforderungen und Vorschriften der Richtlinien 2004 108 EG und 2006 95 EG befindet Die vollständige Konformitätserklärung finden Sie unter www rutenbeck de im Downloadbereich We the Wilhelm Rutenbeck GmbH Co KG declare under our sole responsibility that the patch panel was manufactured according to a certified comprehensive quality ...

Отзывы: