TECHNICAL SPECIFICATIONS

                                       MCA-66 Multizone Controller

 

Dimensions:

  17"W x 3.5"H x 13.4"D (43.2 x 9 x 34 cm)

 

Weight: 

 19.2 lbs. (8.7 kg)

 

Power Supply: 

 100-120 VAC, 60Hz (MCA-66)

 

  220-240 VAC, 50Hz (MCA-66i)

 

Fuse Rating: 

 100-120V/T3.15A 250V US and Canada (MCA-66)

 

  220-240V/T1.25A 250V International (MCA-66i)

 

Frequency Response: 

 20Hz-20kHz +/- 1 dB at 1W output into 8 ohms

 

Watts per channel:

  20W RMS into 8 ohms

 

Total Harmonic Distortion:

  <0.10%

 

Signal to Noise Ratio: 

 93 dB unweighted, 96 dB A-weighted

 

Audio Source Inputs: 

 6 stereo RCA Line-Level, 3 coax,1 optical 

 

  (maximum of 6 total inputs)

  

Audio Zone Outputs: 

 6 Speaker Level 20W/ch

 

  (2 Line Level, fixed or variable selectable)

 

Common Trigger: 

 Out, 12VDC, @100mA

 

Home Theater Trigger: 

 In/Out, 12VDC (pass-through)

 

Page Trigger: 

In, 12VDC

 

Speaker connection: 

  6 detachable 4 pole connectors

 

Keypad ports:

  6 RJ-45 T568A standard 

 

IR Outputs: 

6 routed, 1 common

 

Communication ports:

  USB (firmware update only)

 

  1 Serial RS-232, 19.2 kHz baud rate

 

  1 Ethernet RJ-45, 10/100 Base T 

 

  2 RJ-45 RNET Links In/Out 

LIMITED WARRANTY

Limited Warranty

The Russound MCA-66 Controller Amplifier is guaranteed against all defects 

in materials and workmanship for two (2) years from the date of purchase. 

During this period, Russound will replace any defective parts and correct any 

defect in workmanship without charge for either parts or labor.

For this warranty to apply, the unit must be installed and used according 

to its written instructions. If service is necessary, it must be performed by 

Russound. The unit must be returned to Russound at the owner’s expense and 

with prior written permission. Accidental damage and shipping damage are 

not considered defects, nor is damage resulting from abuse or from servicing 

by an agency or person not specifically authorized in writing by Russound.

This warranty does not cover:

•  Damage caused by abuse, accident, misuse, negligence, or improper 

installation or operation

•  Power surges and lightning strikes
•  Normal wear and maintenance
•  Products that have been altered or modified
•  Any product whose identifying number, decal, serial number, etc. has been 

altered, defaced or removed.

Russound sells products only through authorized Dealers and Distributors 

to ensure that customers obtain proper support and service. Any Russound 

product purchased from an unauthorized dealer or other source, including 

retailers, mail order sellers and online sellers will not be honored or serviced 

under existing Russound warranty policy. Any sale of products by an 

unauthorized source or other manner not authorized by Russound shall void 

the warranty on the applicable product.

Damage to or destruction of components due to application of excessive 

power voids the warranty on those parts. In these cases, repairs will be made 

on the basis of the retail value of the parts and labor. To return for repairs, 

the unit must be shipped to Russound at the owner’s expense, along with a 

note explaining the nature of service required. Be sure to pack the unit in a 

corrugated container with at least three (3) inches of resilient material to 

protect the unit from damage in transit.

Before returning a unit for repair, call Russound Tech Support at 

 

(866) 888-7466 for a Return Authorization number. Write this number on the 

shipping label and ship to:

Russound

: ATTN: Service, 1 Forbes Road, Newmarket, NH 03857

Due to continual efforts to improve product quality as new technology and 

techniques become available, Russound/FMP, Inc. reserves the right to revise 

system specifications without notice.

Содержание MCA-66

Страница 1: ...MCA 66 6 Source 6 Zone Controller Amplifier Installation Manual...

Страница 2: ...net connection is required for obtaining the most recent firmware Note If no internet connection will be available at the installation location please download the latest firmware from the Russound we...

Страница 3: ...Connections 10 Speaker Connections 11 Source Connections 12 Bluetooth and Digital Inputs 13 Ethernet Connection and Factory Reset 13 Multiple Controller Installation 14 Zone 1 and 2 Amplification 15...

Страница 4: ...r Zone Works with RNET smart sources transmitting metadata song artist and other information for display on the keypads Audio paging with a 12v trigger input Party mode Do Not Disturb and source zone...

Страница 5: ...to the All ON command Page Participation defines whether a zone will respond to a page event Page Volume sets the volume of a page event in each zone Power Management of Sources enabled disabled per...

Страница 6: ...CONTROLLER FRONT PANEL Removable cover to access IR window IR Programming IR Receiver Window Zone LED indicators visible behind cover Front Panel Front Panel with cover removed Red IR LED talk back Po...

Страница 7: ...120 240V Input Detachable grounded power cord connection Controller ID Switch Set ID for multiple controller configurations AC Voltage Switch Select appropriate voltage Factory Reset Button A 3 second...

Страница 8: ...A 66 and the source equipment be plugged into a dedicated 20 amp circuit A power line conditioner can reduce interference problems caused by noise found in some electrical systems The power switch for...

Страница 9: ...proved electrical box at the keypad double gang at least 32 cu in and controller locations Using connector specific wall plates at the controller location will better organize all of the incoming cabl...

Страница 10: ...d port to a RJ 45 wall plate optional Using the same T568A RJ 45 wiring configuration use CAT 5e cable from the wall plate to the keypad Maximum CAT 5e cable length is 250 feet between the controller...

Страница 11: ...wire identities straight Strip 1 to 2 inches 2 5 to 5 cm off the end of each speaker cable jacket Then strip 1 4 inch 0 7 cm of insulation off each wire Twist the speaker wire strands together so ther...

Страница 12: ...ound RNET enabled source equipment The connection is made using a CAT 5e patch cable from the Link Out of the controller and into the Link In of the RNET enabled source Another CAT 5e patch cable can...

Страница 13: ...ake up Sources 3 4 and 5 Source 5 can be configured for either Coaxial or Optical digital input Source 3 4 and 5 are configured for Analog inputs by default These source inputs can be configured to be...

Страница 14: ...is only required on Controller 1 in a multi controller system When using the BTC 1X Bluetooth on Source 1 connect the Source 1 OUT on Controller 1 to the Source 1 IN on Controller 2 Continue the audio...

Страница 15: ...or additional amplification when needed such as for outdoor zones or larger rooms The Zone Line Output can be set to Variable default or Fixed Always On Typical Amplifier Connection D250LS two channel...

Страница 16: ...s then only five other source inputs are available Page Trigger IN The page trigger input is used to trigger a page event Paging is configurable per zone using SCS C5 software A 12VDC trigger selects...

Страница 17: ...and to the sources While all zones are still OFF and 12VDC is removed the system will wait 5 minutes and then activate the power management OFF command to the sources System On at least one zone is on...

Страница 18: ...window When using the IR routed outputs in order to control this source component with IR the source must be selected at the keypad receiving the command Common IR This output is supported by the MCA...

Страница 19: ...e front of the controller if the corresponding keypad is on The LED will not be lit if the keypad is not turned on or is absent 10 Check operation of all keypad functions 11 Check for functional IR si...

Страница 20: ...re not considered defects nor is damage resulting from abuse or from servicing by an agency or person not specifically authorized in writing by Russound This warranty does not cover Damage caused by a...

Страница 21: ...ing instructions or as marked on the appliance 12 Main Power Disconnect The power switch is a double pole switch When the switch is in the Off position the appliance is completely disconnected from th...

Страница 22: ...22 Russound MCA 66 Installation Manual...

Страница 23: ...23 Russound MCA 66 Installation Manual...

Страница 24: ...9 5388 email tech russound com www russound com 28 1392 03 24 15 2015 Russound All rights reserved All trademarks are the property of their respective owners Specifications are subject to change witho...

Отзывы: