Russound MCA-66 Installation Manual

SYSTEM START UP

TROUBLESHOOTING

Start up

1.  Make connections of sources, speakers, network and keypads to the 

controller(s). 

2.  In a multiple controller configuration, set the controller IDs to unique 

numbers. Use CAT-5e linking cables of no more than 18 in (45.7 cm) to link 

the controllers. Link by interconnecting the RNET Link ports.

3.  Plug in and power the sources and controllers.
4.  The left LED showing power on the front panel of each controller should 

be lit. The zone lights will cycle in a moving pattern until the controller is 

fully booted, at which time the zone lights will go out.

5.  Unlock the system using your Russound Certified Installer Credentials. 

6.  Perform a firmware update check using either Web-SCS or the SCS-C5 

software.  Update all Russound system components if required. 

7.  Configure the system using WEB-SCS or SCS-C5, depending on the 

requirements of the system configuration. 

8.  Check operation of the keypads, power on, and cycle through sources. 

For correct operation, each RNET source must be configured with a 

unique source ID and must match the assignment made with the SCS-C5 

Configuration software. 

9.  Check zone keypads. The zone LED should be lit on the front of the 

controller if the corresponding keypad is on. The LED will not be lit if the 

keypad is not turned on or is absent.

10.  Check operation of all keypad functions. 
11.  Check for functional IR signal pass-through (if applicable). 
12.  The system is now ready to use.

Troubleshooting

•  When the controller and the keypads are powered ON, all the corresponding 

zone LEDs on the face of the controller will be green. Improper connection 

may cause one or more LEDs not to be lit. Check all connections.

•  Cycle power by pressing the power button, waiting 10 seconds, and then 

pressing the power button again. 

•  Check connections from the keypads and speakers to the controller(s).
•  If a keypad doesn't respond to commands ensure the OS update jumper on 

the rear of the keypad is in the RUN position (on the lower pins). 

Factory Initialization

If SCS-C5 cannot connect to the MCA-66, follow these steps to perform a 

network configuration reset.

• Press and hold the Reset button on the rear of the controller for 3 seconds 

and release.

For a full factory initialization, erasing all configuration settings:

• Press and hold the Reset button on the rear of the controller for 10 

seconds.

Note: 

Performing a factory initialization will restore the unit to its factory 

default state, including software lockdown.  The unit will require valid 

Russound Certified Installer credentials and an internet connection in order to 

unlock the device again.

Содержание MCA-66

Страница 1: ...MCA 66 6 Source 6 Zone Controller Amplifier Installation Manual...

Страница 2: ...net connection is required for obtaining the most recent firmware Note If no internet connection will be available at the installation location please download the latest firmware from the Russound we...

Страница 3: ...Connections 10 Speaker Connections 11 Source Connections 12 Bluetooth and Digital Inputs 13 Ethernet Connection and Factory Reset 13 Multiple Controller Installation 14 Zone 1 and 2 Amplification 15...

Страница 4: ...r Zone Works with RNET smart sources transmitting metadata song artist and other information for display on the keypads Audio paging with a 12v trigger input Party mode Do Not Disturb and source zone...

Страница 5: ...to the All ON command Page Participation defines whether a zone will respond to a page event Page Volume sets the volume of a page event in each zone Power Management of Sources enabled disabled per...

Страница 6: ...CONTROLLER FRONT PANEL Removable cover to access IR window IR Programming IR Receiver Window Zone LED indicators visible behind cover Front Panel Front Panel with cover removed Red IR LED talk back Po...

Страница 7: ...120 240V Input Detachable grounded power cord connection Controller ID Switch Set ID for multiple controller configurations AC Voltage Switch Select appropriate voltage Factory Reset Button A 3 second...

Страница 8: ...A 66 and the source equipment be plugged into a dedicated 20 amp circuit A power line conditioner can reduce interference problems caused by noise found in some electrical systems The power switch for...

Страница 9: ...proved electrical box at the keypad double gang at least 32 cu in and controller locations Using connector specific wall plates at the controller location will better organize all of the incoming cabl...

Страница 10: ...d port to a RJ 45 wall plate optional Using the same T568A RJ 45 wiring configuration use CAT 5e cable from the wall plate to the keypad Maximum CAT 5e cable length is 250 feet between the controller...

Страница 11: ...wire identities straight Strip 1 to 2 inches 2 5 to 5 cm off the end of each speaker cable jacket Then strip 1 4 inch 0 7 cm of insulation off each wire Twist the speaker wire strands together so ther...

Страница 12: ...ound RNET enabled source equipment The connection is made using a CAT 5e patch cable from the Link Out of the controller and into the Link In of the RNET enabled source Another CAT 5e patch cable can...

Страница 13: ...ake up Sources 3 4 and 5 Source 5 can be configured for either Coaxial or Optical digital input Source 3 4 and 5 are configured for Analog inputs by default These source inputs can be configured to be...

Страница 14: ...is only required on Controller 1 in a multi controller system When using the BTC 1X Bluetooth on Source 1 connect the Source 1 OUT on Controller 1 to the Source 1 IN on Controller 2 Continue the audio...

Страница 15: ...or additional amplification when needed such as for outdoor zones or larger rooms The Zone Line Output can be set to Variable default or Fixed Always On Typical Amplifier Connection D250LS two channel...

Страница 16: ...s then only five other source inputs are available Page Trigger IN The page trigger input is used to trigger a page event Paging is configurable per zone using SCS C5 software A 12VDC trigger selects...

Страница 17: ...and to the sources While all zones are still OFF and 12VDC is removed the system will wait 5 minutes and then activate the power management OFF command to the sources System On at least one zone is on...

Страница 18: ...window When using the IR routed outputs in order to control this source component with IR the source must be selected at the keypad receiving the command Common IR This output is supported by the MCA...

Страница 19: ...e front of the controller if the corresponding keypad is on The LED will not be lit if the keypad is not turned on or is absent 10 Check operation of all keypad functions 11 Check for functional IR si...

Страница 20: ...re not considered defects nor is damage resulting from abuse or from servicing by an agency or person not specifically authorized in writing by Russound This warranty does not cover Damage caused by a...

Страница 21: ...ing instructions or as marked on the appliance 12 Main Power Disconnect The power switch is a double pole switch When the switch is in the Off position the appliance is completely disconnected from th...

Страница 22: ...22 Russound MCA 66 Installation Manual...

Страница 23: ...23 Russound MCA 66 Installation Manual...

Страница 24: ...9 5388 email tech russound com www russound com 28 1392 03 24 15 2015 Russound All rights reserved All trademarks are the property of their respective owners Specifications are subject to change witho...

Отзывы: