65
IO name
IO size,
B
IO value range IO value explanation
Notes
GSM signal level
1
0-31
0=-115dBm or less
1=-111dBm
2...30=-110...-54dBm
31=-52dBm or
greater
99=not known or
detectable
ECO
overspeeding
timer
2
0-65535
Time whed speed
was above limit
ECO RPM in red
band timer
2
0-65535
Time when RPM was
not optimal
Fuel Counter 1
2
0-65535
Depends on Counter
Fuel Counter 2
2
0-65535
Depends on Counter
GPS speed
1
0-255
Value km/h
GSM operator
4
0-4294967295
Unique Mobile
operator code
http://en.wikipedia.or
g/wiki/Mobile_Netwo
rk_Code
iButton ID
8
-
Unique iButton ID
Ignition(DIN4)
1
0-1
0=low level on input
1=high level on input
Movement
sensor
1
0-1
0=No motion
detected
1=Motion detected
Modem
temperature
1
-40-90
°C
PCB
temperature
1
-40-80
°C
Power supply
voltage
2
0-65535
mV
TCO distance
4
0-4294967295
5 m/Bit gain
10000=50000m
TCO engine
speed
2
0-65535
0.125 rpm / Bit gain
8000=1000rpm
FM
Manual
Содержание ECO3
Страница 1: ... All rights reserved to Ruptela UAB User Manual FM ECO3 PRO3 TCO3 Version 7 Last update 2013 08 27 ...
Страница 11: ... All rights reserved to Ruptela UAB P a g e 11 2 6 FM PRO 3 DIMENSIONS FM Pro3 ...
Страница 21: ... All rights reserved to Ruptela UAB P a g e 21 3 6 FM ECO3 DIMENSIONS FM Eco3 ...
Страница 29: ... All rights reserved to Ruptela UAB P a g e 29 4 6 FM TCO3 DIMENSIONS FM Tco3 ...
Страница 48: ... All rights reserved to Ruptela UAB P a g e 48 Fig 5 3 3 2 Timetable view FM Manual ...