RG-IS2700G Series Switch Hardware Installation and Reference Guide
Rated current: 0.4 A
Power cord specification: 10 A power cord
Heat Dissipation
The RG-IS2712G switch is designed with no fans. To ensure good dissipation, sufficient ventilation space (10 cm distance
from both sides and the back panel of the chassis) should be reserved to avoid the air inlet of the chassis from being
blocked; otherwise, the dissipation might be affected.
LED Indicators
Indicator
Faceplate
Marker
Status
Meaning
Status indicator
Status
Off
The switch is not powered on.
Blinking green
The switch is being initialized. If the blinking
persists, however, it indicates that an
abnormality occurs.
Solid green
The switch is operational.
Solid yellow
It indicates a warning on the switch temperature.
Check the working environment of the switch
immediately.
Solid red
Indicates a fault on the switch. For details, refer
to Section of
Troubleshooting Common
Faults
.
RJ-45 port indicator
1~8
Off
No link, or port was administratively shut down.
Solid green
Link present.
Blinking green
Activity. The port is receiving or sending data.
SFP port indicator
9F-12F
Off
No link, or port was administratively shut down.
Solid green
Link present.
Blinking green
Activity. The port is receiving or sending data.
1.2 RG-IS2706G
Technical specifications
Table 1-3 Technical specifications of the RG-IS2706G Switches
Model
RG-IS2706G
Module Type
Gigabit Ethernet:
MINI-GBIC-SX-MM850
MINI-GBIC-LX-SM1310
MINI-GBIC-LH40-SM1310
MINI-GBIC-ZX50-SM1550
MINI-GBIC-ZX80-SM1550
MINI-GBIC-ZX100-SM1550