Hardware Installation and Reference Guide                                                                                            Preparing for Installation 

Preparing for Installation 

2.1   

Safety Precautions 

 

Note 

 

To avoid personal injury and device damage, carefully read the safety precautions before you install the 

device. 

 

The following safety precautions may not cover all possible dangers. 

 

2.1.1  

General Safety Precautions 

  Do not expose the AP to high temperature, dusts, or harmful gases.   

  Do not install the AP in an inflammable or explosive environment.   

  Keep the AP away from EMI sources such as large radar stations, radio stations, and substations.   

  Do not subject the AP to unstable voltage, vibration, and noises. 

  The installation site should be free from water flooding, seepage, dripping, or condensation. The installation 

site  should  be  selected  according  to  network  planning  and  communications  equipment  features,  and 

considerations such as climate, hydrology, geology, earthquake, electrical power, and transportation.   

  Keep the AP at least 500 meters away from the ocean and do not face it towards the sea breeze.   

  Do not place the device in walking areas. 

  During the installation and maintenance, do not wear loose clothes, ornaments, or any other things that may 

be hooked by the chassis. 

  Keep tools and components away from walking areas. 

2.1.2  

Handling Safety 

  Prevent the device from being frequently handled. 

  Cut off all the power supplies and unplug all power cords before moving or handling the device. 

2.1.3  

Electric Safety 

 

Warning 

 

Improper or incorrect electric operations may cause a fire, electric shock, and other accidents, and lead to 

severe and fatal personal injury and device damage. 

 

Direct or indirect contact with high voltage or mains power supply via wet objects may cause fatal 

dangers. 

 

  Observe  local  regulations  and  specifications  during  electric  operations.  Only  personnel  with  relevant 

qualifications can perform such operations. 

  Check whether there are potential risks in the work area. For example, check whether the power supply is 

grounded, whether the grounding is reliable, and whether the ground is wet. 

Содержание RG-AP810-L

Страница 1: ...Ruijie RG AP810 L Access Point Hardware Installation and Reference Guide Document Version V1 1 Date 2022 9 7 Copyright 2022 Ruijie Networks...

Страница 2: ...are subject to commercial contracts and terms Some or all of the products services or features described in this document may not be within the scope of your purchase or use Unless otherwise agreed i...

Страница 3: ...escribed as follows Danger An alert that calls attention to safety operation instructions that if not understood or followed when operating the device can result in physical injury Warning An alert th...

Страница 4: ...echnical specifications and specifications and usage guidelines for cables and connectors It is intended for the users who have some experience in installing and maintaining network hardware At the sa...

Страница 5: ...e Contents 3 1 3 Technical Specifications 3 1 3 1 Size and Weight 3 1 3 2 RF 4 1 3 3 Ports 5 1 3 4 Power Supply 5 1 3 5 Environment and Reliability 5 1 1 Indicator and Button Description 6 2 Preparing...

Страница 6: ...pace Requirement 9 2 2 4 Temperature Humidity Requirements 9 2 2 5 Cleanliness Requirements 10 2 2 6 Anti interference Requirements 11 2 2 7 Lightning Protection Requirements 11 2 2 8 Installation Sit...

Страница 7: ...3 8 1 Precautions 19 3 8 2 Bundling Steps 19 3 9 Checking after Installation 19 3 9 1 Checking the Access Point 19 3 9 2 Checking Cable Connection 20 3 9 3 Checking Power Supply 20 4 Verifying Operat...

Страница 8: ...oubleshooting Cases 23 6 2 1 Ethernet Port Does Not Work After Being Connected to an Ethernet Cable 23 6 2 2 Indicator Is Off for a Long Time 23 6 2 3 Indicator Remains Red for a Long Time 24 6 2 4 In...

Страница 9: ...Hardware Installation and Reference Guide Product Overview 5 7 2 Cabling Recommendations 27 7 3 Power Supply 30...

Страница 10: ...provides a combined data rate of 1 775 Gbps with up to 574 Mbps in the 2 4 GHz band and 1 201 Gbps in the 5 GHz band available for flexible deployments in the field of education government finance an...

Страница 11: ...Hardware Installation and Reference Guide Product Overview 2 Figure 1 2 Front Panel Table 1 1 Front Panel No Item Description 1 LED Indicate the operation status of device Figure 1 3 Side View...

Страница 12: ...mission IEEE 802 3af compliant 5 DC power plug Connect to the DC power adapter to supply power to the AP 1 2 Package Contents Table 1 3 Package Contents Item Quantity RG AP810 L Access Point 1 Mountin...

Страница 13: ...Frequency Radio1 802 11b g n ax 2 4 GHz to 2 483 GHz HE40 Radio2 802 11a n ac ax 5 150 GHz 5 350 GHz HE80 802 11a n ac 5 470 GHz 5 725 GHz 5 725 GHz 5 850 GHz HE80 country specific restrictions apply...

Страница 14: ...le 1 6 Ports Item Description Bluetooth Bluetooth 5 1 Fixed Service Port One 10 100 1000 Base T Ethernet port IEEE 802 3af compliant PoE Fixed Management Port One RJ45 Console port GPS Not support LED...

Страница 15: ...6 2015 GB T 17618 2015 1 1 Indicator and Button Description Note In the description of the indicator status unless otherwise specified the indicator status description applies to both Fit AP and Fat A...

Страница 16: ...g blue On for 1s Off for 1s The software system is running normally The AP is working normally and wireless users are online Fast blink in red On for 0 2s Off for 0 2s In Fit AP mode the AP enables th...

Страница 17: ...transportation Keep the AP at least 500 meters away from the ocean and do not face it towards the sea breeze Do not place the device in walking areas During the installation and maintenance do not wea...

Страница 18: ...1 Bearing Requirements Evaluate the weight of the device and its accessories for example the bracket and power supply modules and ensure that the ground of the installation site meets the requirement...

Страница 19: ...nt Dust particles diameter 0 5 m Particles m3 1 4 10 7 Dust particles 0 5 m diameter 1 m Particles m3 7 10 5 Dust particles 1 m diameter 3 m Particles m3 2 4 10 5 Dust particles 3 m diameter 1 m Parti...

Страница 20: ...You are advised to install a power lightning arrester in front of the power input end to enhance the lightning prevention for the power supply 2 2 8 Installation Site Requirements Regardless of wheth...

Страница 21: ...are there and make sure that The installation position provides sufficient space for heat dissipation The installation position meets the temperature and humidity requirements of the device The power...

Страница 22: ...pattern and diameter should meet the requirements in Table 1 4 Figure 3 1 Mounting Bracket 3 3 Precautions To avoid damage to the AP observe the following safety precautions Do not power on the device...

Страница 23: ...can get the optimal coverage In the indoor area the signal coverage of the ceiling mounted device is larger than that of the wall mounted device Please choose the ceiling mounting method first 3 4 1...

Страница 24: ...Bracket Caution The AP can be installed in any of four directions on the mounting bracket depending on how you route the Ethernet cable The square feet should fit easily into the mounting slots Do no...

Страница 25: ...the rear of the AP with the mounting holes on the bracket Figure 3 6 Aligning the Square Feet with the Mounting Holes Caution Install the Ethernet cables before mounting the AP on the bracket 3 Slide...

Страница 26: ...the slots After installation verify that the AP is securely fastened 3 5 Securing the Access Point 1 Loosen the screw on the mounting bracket and engage the security screw Figure 3 8 Engaging the Secu...

Страница 27: ...ss Point 1 If the AP is installed on the ceiling hold the AP in your hands and slide it sideways and away from the bracket in the LAN port direction Figure 3 10 Removing the Ceiling mounted AP 2 If th...

Страница 28: ...g Cables 3 8 1 Precautions Make sure the cable bundles are neat and orderly Bend twisted pairs naturally or to a large radius close to the connector Do not over tighten cable bundle as it may reduce t...

Страница 29: ...hecking Cable Connection Make sure the UTP STP cable matches the interface type Make sure cables are properly bundled 3 9 3 Checking Power Supply Make sure all power ports are properly connected and c...

Страница 30: ...n the AP is connected to a PC verify that the PC and PoE switch are properly grounded 4 2 Powering up the AP 4 2 1 Checking Environment before Power on Verify that the power supply is properly connect...

Страница 31: ...he device to remotely monitor the configurations and status of the AP Note You can log in to the AP via Telnet and use monitoring related commands to maintain the AP 5 2 Remote Maintenance If the AP o...

Страница 32: ...working normally and then check whether the Ethernet cable matches the current working speed In addition check whether the cable is connected normally 6 2 2 Indicator Is Off for a Long Time PoE power...

Страница 33: ...e indicator fast blinks in blue during software upgrade When the software upgrade is finished the indicator is steady blue Note The software upgrade time is uncertain so do not turn off the device whe...

Страница 34: ...d with a maximum distance of 100 meters 328 feet 1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure 7 1 Figure 7 1 1000BASE T Connection 10BASE T uses Ca...

Страница 35: ...Hardware Installation and Reference Guide Appendix 26 Figure 7 3 100BASE TX 10BASE T Connection...

Страница 36: ...gged the bend radius should be 10 times the overall diameter The minimum bend radius of a high speed cable such as an SFP cable should be 5 times the overall diameter of the cable If the cable is cons...

Страница 37: ...sition where device operation is not affected and no damages occur to the device and cables during debugging Do not bind power cords to the rails for moving parts Leave a certain length of the cable c...

Страница 38: ...rews to fasten terminals Bundle cables of the same type and running in the same direction into groups Keep cables clean and straight Cables shall be tied according to the following table Diameter of C...

Страница 39: ...7 3 Power Supply DC power adapter Input voltage 48 V Rated current 0 3 A Technical Specifications of the DC Power Connector Inner Diameter Outer Diameter Depth Polarity 2 0 mm 0 08 in 6 3 mm 0 25 in 9...

Отзывы: