background image

3. PWR2 2 status indicator 

4. MGMT management interface indicator 

5. Fan indicator   

6. USB2.0 port 

7. 10/100/1000Base-T MGMT Ethernet port 

8. Console port 

9. 10G SFP+ port 

10. Port status indicator 

11. Extension slot 

1.3.1.2 Ports on the Backpanel 

The backpanel of the RG-S6200 switch provides the slots for the power supply modules and fan modules. The 
RG-S6200 supports two dissipation schemes: front-to-back air passage (-F) and back-to-front air passage (-R). 
Therefore, the backpanel is marked with two formats: M6200-FAN-F and M6200-FAN-R. That is, for the –F: the air 
flows in from one-side of the front panel port and out from the backpanel; while for the –R: the air flows in from the 
backpanel and out from one-side of the front panel port. 

 

Figure 1-3 Schematic diagram of RG-S6200 backpanel with M6200-FAN-F(R) +RG-M6200-AC650I-F(R) 

1. Power supply module1 slot (take the RG-M6200-AC650I-F(R) fan module for the example) 

2. Fan module slot (take the M6200-FAN-F(R) fan module for the example) 

3. Fan module slot (take the M6200-FAN-F(R) fan module for the example) 

4. Fan module slot (take the M6200-FAN-F(R) fan module for the example) 

5. Fan module slot (take the M6200-FAN-F(R) fan module for the example) 

6. Power supply module2 slot (take the RG-M6200-AC650I-F(R) fan module for the example) 

7. Grounding pole   

8. Power supply module1 RG-M6200-AC650I-F(R) status indicator 

9. Fan module M6200-FAN-F(R) status indicator 

10. Fan module M6200-FAN-F(R) status indicator 

11. Fan module M6200-FAN-F(R) status indicator 

12. Fan module M6200-FAN-F(R) status indicator 

1.3.1.3 Power Supply System 

Power supply requirements: 

AC input. 

Rated pressure range: 100-240V~ 

Maximum pressure range: 90-264~ 

Frequency: 50-60Hz 

Содержание RG-S6200 Series

Страница 1: ...Installation Manual RG S6200 Series Switch...

Страница 2: ...means are all registe red trademarks of Ruijie Networks Co Ltd and are protected by law Disclaimer The information contained in this manual may be modified without notification Ruijie Networks has tri...

Страница 3: ...d Connection Media Appendix B Mini GBIC Modules Appendix C SFP Modules Related Documents Software manual of switches covering CLI commands software configuration guide and version release notes Obtain...

Страница 4: ...e configuration problems and other network performance problems http www ruijie com cn service aspx Customer services hotline 86 4008 111 000 Customer services email service ruijie com cn Documentatio...

Страница 5: ...es Model 10 100 1000Base T adaptive Ethernet port 10G SFP port Console port USB2 0 port Extension Module Slot Redundant Fan Redundant Power Supply RG S6200 48XS 1 32 1 1 1 3 1 3 1 The extension module...

Страница 6: ...ie Networks SFP Port Supported SFP Port Supported RPS type 1 1 redundant power supply Power supply AC input Rated pressure range 100 240V Maximum pressure range 90 264V Maximum DC power supply 280V Fr...

Страница 7: ...one 10 100 1000Base T Ethernet port and one USB2 0 port The backpanel provides two power slots and four dual fan slots Figure1 1 shows the appearance of the M6200 16XS extension module Figure 1 1 Appe...

Страница 8: ...ure 1 3 Schematic diagram of RG S6200 backpanel with M6200 FAN F R RG M6200 AC650I F R 1 Power supply module1 slot take the RG M6200 AC650I F R fan module for the example 2 Fan module slot take the M6...

Страница 9: ...pation System The RG S6200 supports two heat dissipation schemes F and R The F mode combines the front to back air passage with power backward heat dissipation thereby ensuring the device to function...

Страница 10: ...take and outlet exceeds the normal operating temperature of the system B The inconsistency of power supply fan type occurs The inconsistency means the F and R coexist in the system Note that the F and...

Страница 11: ...olid red Power supply fault any fault Solid green Gigabit Link Blinking green Gigabit ACT Solid yellow 10 100M Link MGMT Indicates the external management port Blinking yellow 10 100M ACT Solid green...

Страница 12: ...port 10G SFP fiber port the fiber port supports 10GBase X mode A variety of optical transceiver modules of Ruijie Networks are available for different transmission distances Features are shown as belo...

Страница 13: ...0 AC650I F R Figure1 8 RG M6200 AC650I F R power supply module 1 Power supply status indicator 2 Power plug 1 5 2 2 Features RG M6200 AC650I F R provides the power supply with rated voltage of 12V for...

Страница 14: ...Fan status indicator 1 5 3 2 Features M6200 FAN F R provides the heat dissipation schemes of the front and back air passages back and front air passages to enable the intelligent dissipation for the R...

Страница 15: ...fan status indicator which is defined as below Automatically adjust the rotation speed of the fan according to the temperature Solid green The fan works normally Solid yellow The module type conflict...

Страница 16: ...or straining the back Before moving the device turn off all power supplies and dismantle all power modules 2 1 3 Electric Safety Observe local regulations and specifications when performing electric o...

Страница 17: ...lane of the cabinet is reserved at the ventilation openings to ensure the normal ventilation After various cables have been connected they should be arranged into bundles or placed on the cabling rack...

Страница 18: ...osion of the metal and the aging of some parts The equipment room should be protected from the intrusion of harmful gases such as sulfur dioxide sulfured hydrogen nitrogen dioxide and chlorine whose r...

Страница 19: ...ply and the enclosure in the equipment electric shock may occur 2 3 2 Lightning Grounding The lightning protection system of a facility is an independent system that consists of the lightning rod down...

Страница 20: ...nducts from one unit to another Conducted interference often affects the power supply of the equipment but can be controlled by a filter Radiated interference may affect any signal path in the equipme...

Страница 21: ...The RG S6200 series are not provided with a tool kit Please prepare tools on your own...

Страница 22: ...ensure that you have carefully read Chapter 2 Make sure that the requirements set forth in Chapter 2 have been met 3 1 Installation Procedure 3 2 Confirmations before Installation Before installation...

Страница 23: ...pad radar launch pad and high frequency large current devices If necessary electromagnetic shielding should be adopted For example use interface cables to shield cables Interface cables should be lai...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ...to the Desktop In several cases users do not have the 19 inch standard cabinets In this case the most frequent method is to mount the switch to a clean workstation Step 1 Attach the four adhesive rubb...

Страница 28: ...to avoid being pressed by heavy goods or disconnected by foots 3 4 1 2 Removing theExtension Module The process of removing the extension module is reverse to the installation 1 Power off the switch...

Страница 29: ...power module you need to hold the handle of the power module with one hand and hold the end of the power module with the other hand to remove it slowly The blank panel of the power shall be installed...

Страница 30: ...he process of removing a fan module is reverse to the installation Step 1 Wear the anti static gloves and loosen the captive screws of the fan module to be replaced Step 2 Pinch the captive screws of...

Страница 31: ...round line is connected Check that the cables and power input cables are correctly connected Check that all interface cables are laid out inside the equipment room In the case of external cabling chec...

Страница 32: ...the PC Step 2 Connect one end of the console cable RJ45 to the console port of the switch 4 1 3 Setting Terminal Parameters Step 1 Start the PC and run the terminal simulation program on the PC such a...

Страница 33: ...the parameters are already configured 4 2 2 Checking after Power on Recommended After power on you are recommended to perform the following checks to ensure the normal operation of follow up configura...

Страница 34: ...mer Service Department for technical support The status indicator is not on after the switch is started The power supply module does not supply power The power cable is in loose contact Check whether...

Страница 35: ...s in receiving transmitting frames The connected twisted pair cable is faulty The length of the cable exceeds 100 m The port has special configuration that has no common working mode with the connecte...

Страница 36: ...igure A 1 Schematic diagram for the four twisted pairs of the 1000BASE T Straight Through Crossover Switch Switch 1TP0 1TP0 2TP0 2TP0 3TP1 3TP1 6TP1 6TP1 4TP2 4TP2 5TP2 5TP2 7TP3 7TP3 8TP3 8TP3 Switch...

Страница 37: ...orts select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4 Schematic diagram for...

Страница 38: ...MHz km Core Size nm Transmis sion Distance Send Optical Intensity dbm Min Receptio n Sensitivit y dbm MAX Standard Complian ce Mini GBIC SX 850 Multi mo de optical fiber 160 200 400 500 62 5 62 5 50 0...

Страница 39: ...m N A N A For the optical module with transmission distance exceeding 40km and higher one on line optical attenuator should be added on the link to avoid the overload of the optical receiver when shor...

Страница 40: ...m Media Type Core Size nm Modular Bandwid th MHz km Transmiss ion Distance Optical Intensi ty dbm MIN Optical Intensi ty dbm MAX Receptio n Sensitivit y dbm MIN Receptio n Sensitiv y dbm MAX 62 5 200...

Страница 41: ......

Отзывы: