![Ruijie Networks RG-EasyGate Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/ruijie-networks/rg-easygate-series/rg-easygate-series_hardware-installation-manual_1499724015.webp)
RG-EasyGate Series Hardware Installation Guide V1.28
Copper Indicators
Solid orange indicates the 10 M/100 M link that the port connects to is
up.
Blinking indicates data is being transceived at the port.
Indicators of 0F-7F Gigabit
Optical Ports
The green in-position LED is on when the optical module is inserted.
Solid green indicates the link that the port connects to is up.
Blinking green indicates data is being transceived at the port.
BYPASS Indicators of the
OBS0, OBS1 Optical port
Solid green indicates the power supply is working.
Off indicates no power supply.
Power Modules
RG-PA300I Power Module
Module Appearance and Indicators
Figure 1-11 Appearance of the RG-PA300I Power Module
Table 1-11 Indicator Description of the RG-PA300I Power Module
LED Indicator
Working Status
IN
Solid green indicates normal power input.
Off indicates abnormal power input.
OUT
Solid green indicates normal power output
Off indicates abnormal power output.
FAIL
Off indicates the power supply is working properly.
Solid red indicates the abnormal power supply.
Module Attributes
Table 1-12 Attribute Description of the RG-PA300I Power Module
Attributes
Description
Rated Input Value
100–240 V; 50–60 Hz; 6.5 A
Rated Output Value
12 V: 1–25 A
12 V FAN: 0–5 A
Rated Output Power
300 W
Hot Swapping
Supported
N+1 Backup
Supported
Power Factor Correction (PFC)
Supported
Protection Features
Input over-voltage and under-voltage protection, output
over-voltage protection, over-current protection, short-circuit
protection and over-temperature protection.
Communication Features
Supports to communicate with the host to obtain information