Tumbler MPR 150 / 220
5
b)
Check the safety switch on the lid drive; to this end: Open lid
all the way. - When reaching the
“Open”
end position the lid
and indication must remain on the display. - Now close the lid
fully. - When reaching the
“Closed”
end position the lid and in-
dication must remain on the display. If the lid or indication on
the display do not remain, the machine must be shut down
immediately! Error messages of the control system must be
heeded!
c)
Check the safety switches as follows:
–
Start the machine.
–
Press the emergency-stop switch.
–
If
the machine has not switched off, it must be shut down im-
mediately!
!!! To shut down the machine, the emergency-stop switch must be
pushed to
“Emergency
-
Stop”
, the main switch turned to
“0 –
OFF”
and
the power plug pulled from the outlet! Take the Table PC from the
bracket and switch it off permanently. The machine must be secured
against further use!
!!! The supervisor must arrange for the repair of the non-functional
safety device by a Rühle service technician. Until the corresponding
parts have been repaired, the supervisor must ensure that the ma-
chine or parts of the machine are under no circumstances put into op-
eration!
!!! The cleaning personnel must observe the work procedures from the
“Cleaning”
work instructions prepared by the supervisor.
!!! The maintenance personnel may only carry out work specified as
“Regular care”
, unless any other authorisation has been issued in
writing by the manufacturer of the machine. The maintenance per-
sonnel must observe the work procedures from the
“Maintenance”
work instructions prepared by the supervisor.
The power plug must be disconnected for maintenance work!
!!! The machine may not be modified.