10
FX5-208160-030
208
3.0
1
2.7
2,700
14.4
18.0
12
20
11.2
6.2
10406
10557
FX5-208160-050
208
5.0
1
2.7
4,700
24.0
30.0
10
30
18.6
10.3 10407
10557
FX5-208160-075
208
7.5
1
2.7
7,200
36.1
45.1
6
50
27.9
15.5 10408
10557
FX5-208160-100
*
208
10.0
1
2.7
9,690
48.1
60.1
4
70
37.2
20.7 10409
10558
FX5-208360-030
208
3.0
3
1.4
2,700
8.3
10.4
14
15
11.2
6.2
10406
10557
FX5-208360-050
208
5.0
3
1.4
4,700
13.9
17.4
12
20
18.6
10.3 10407
10557
FX5-208360-075
208
7.5
3
1.4
7,200
20.8
26.0
10
30
27.9
15.5 10408
10557
FX5-208360-100
208
10.0
3
1.4
9,700
27.8
34.8
8
35
37.2
20.7 10409
10557
FX5-240160-030
240
3.0
1
2.7
2,700
12.5
15.6
12
20
11.2
6.2
10410
10557
FX5-240160-050
240
5.0
1
2.7
4,700
20.8
26.0
10
30
18.6
10.3 10411
10557
FX5-240160-075
240
7.5
1
2.7
7,200
31.3
39.1
8
40
27.9
15.5 10412
10557
FX5-240160-100
240
10.0
1
2.7
9,700
41.7
52.1
6
60
37.2
20.7 10413
10558
FX5-240160-150
*
240
15.0
1
1.4
14,400
62.5
78.1
2
80
27.1
15.1 10424
10558
FX5-240360-030
240
3.0
3
1.4
2,700
7.2
9.0
14
15
11.2
6.2
10410
10557
FX5-240360-050
240
5.0
3
1.4
4,700
12.0
15.0
14
15
18.6
10.3 10411
10557
FX5-240360-075
240
7.5
3
1.4
7,200
18.0
22.5
10
25
27.9
15.5 10412
10557
FX5-240360-100
240
10.0
3
1.4
9,700
24.1
30.1
8
35
37.2
20.7 10413
10557
FX5-240360-150
240
15.0
3
1.4
14,400
36.1
45.1
6
50
27.1
15.1 10424
10558
FX5-480160-030
° 480
3.0
1
1.3
2,700
6.3
7.9
14
15
11.2
6.2
10414
10557
FX5-480160-050
° 480
5.0
1
1.3
4,700
10.4
13.0
14
15
18.6
10.3 10415
10557
FX5-480160-075
° 480
7.5
1
1.3
7,200
15.6
19.5
12
20
27.9
15.5 10416
10557
FX5-480160-100
° 480
10.0
1
1.3
9,700
20.8
26.0
10
30
37.2
20.7 10417
10557
FX5-480160-150
° 480
15.0
1
1.3
14,400
31.3
39.1
8
40
27.1
15.1 10426
10557
FX5-480160-200
° 480
20.0
1
1.3
19,400
41.7
52.1
6
60
36.1
20.1 10218
10558
FX5-480360-030
480
3.0
3
0.7
2,700
3.6
4.5
14
15
11.2
6.2
10414
10557
FX5-480360-050
480
5.0
3
0.7
4,700
6.0
7.5
14
15
18.6
10.3 10415
10557
FX5-480360-075
480
7.5
3
0.7
7,200
9.0
11.3
14
15
27.9
15.5 10416
10557
FX5-480360-100
480
10.0
3
0.7
9,700
12.0
15.0
14
15
37.2
20.7 10417
10557
FX5-480360-150
480
15.0
3
0.7
14,400
18.0
22.5
10
25
27.1
15.1 10426
10557
FX5-480360-200
480
20.0
3
0.7
19,400
24.1
30.1
8
35
36.1
20.1 10218
10557
FX5-480360-250
480
25.0
3
1.0
24,200
30.1
37.6
8
40
45.2
25.1 10430
10557
FX5-480360-300
480
30.0
3
1.0
29,200
36.1
45.1
6
50
26.4
14.6 10431
10558
FX5-480360-350
480
35.0
3
1.0
34,200
42.1
52.6
6
60
30.7
17.1 10432
10558
FX5-600360-030
600
3.0
3
0.6
2,700
2.9
3.6
14
15
11.2
6.2
10418
10557
FX5-600360-050
600
5.0
3
0.6
4,700
4.8
6.0
14
15
18.6
10.3 10419
10557
FX5-600360-075
600
7.5
3
0.6
7,200
7.2
9.0
14
15
27.9
15.5 10420
10557
FX5-600360-100
600
10.0
3
0.6
9,700
9.6
12.0
14
15
37.2
10.0 10421
10557
FX5-600360-150
600
15.0
3
0.6
14,400
14.4
18.0
12
20
27.1
15.1 10427
10557
FX5-600360-200
600
20.0
3
0.6
19,400
19.2
24.0
10
25
36.1
20.1 10428
10557
FX5-600360-250
600
25.0
3
0.8
24,200
24.1
30.1
8
35
45.2
25.1 10433
10557
FX5-600360-300
600
30.0
3
0.8
29,200
28.9
36.1
8
40
26.4
14.6 10434
10557
FX5-600360-350
600
35.0
3
0.8
34,200
33.7
42.1
8
45
30.7
17.1 10435
10557
FX5 TECHNICAL DATA FOR 60 HZ ELECTRIC AIR HEATERS
MODEL
oF
oC
VOLTAGE
(V)
NOTE
PHASE
NOMINAL
WATTAGE
(kW)
MAX.
MOTOR
NAMEPLATE
CURRENT
(A)
HEATER
WATTAGE
(W)
TOTAL
CURRENT
(A)
MINIMUM
CIRCUIT
AMPACITY
(A)
SUPPLY
WIRE
SIZE
(AWG)
MAXIMUM
FUSE SIZE
(A)
TEMPERATURE
RISE
CORE
PART
NUMBER
CONTACTOR
PART
NUMBER
C US
NOTES:
*
Exceeds the 48 Amp Circuit limit of NEC 424-22. DS5 not available for these units.
° 480 1 phase units
1. Minimum conductor size for 30˚C (86˚F) ambient. Derate conductor for ambient temperature. Use minimum 90˚C (194˚F) insulation.
2. Heater is functioning normally if at rated voltage the amp draw is within 10% of the value in this table.
3. Operation at lower voltages will result in reduced heat output and amp draw
4. Add “T” to model number when adding a built-in thermostat
5. Add “D” to model number when adding a built-in disconnect switch
6. Add “P” to model number when adding a built-in pilot light
7. Add “S” to model number when adding a 3-way switch
8. Add “H” to model number for units with high “off” (deenergized) ambient temperatures
9. Add "U" to model number for units with continuous fan option
10. Add "A" to model number for units with stainless steel cabinet.