9.
Operation
9.1. Control unit
9.1.1.
Adjustment of the control unit parameter
1
)
Mode Button
2
)
ON/OFF Button
A
)
Button
A
:
B
)
Button
B
:
3
)
Control cable
4
)
Display
The control unit enables the control and input of the unit‘s various functions. The control unit has
an integrated temperature sensor (set-point sensor) for measuring the room temperature. The dis-
play shows the various operating parameters and error messages. You can select individual menu
points or change values with the various buttons.
Fig. 9:
Control unit
4
1
21,0°
1
0%
8
4%
2
A
B
3
1 ENGLISH
OFF
8
P 1
V 1.0
P 2
V 1.0
To be able to make changes to the control unit parameter, you must press the „Mode button“
(
M
) for at least 5 seconds.
P 1
will appear on the display. Use button
A
(
▲
) to change to your
desired parameter.
P 1
V 1.0
5 sec
M
A
OFF
8
2 sec
M
B
P 1 Unit control system
Range of values
0 =
Air handling units
0
1 =
Constant pressure control
Factory
setting
P 2 Language setting
Range of values
Factory
setting
P 1 Unit control system
The control unit adapts automatically to the
unit‘s control system with which it works. This
can be checked under the menu point for con-
trol unit parameter
P 1
. Now press button
B
▲
and the control unit will change to input mode.
Now you can use the button
A
(
▲
and
▼
) to make changes in the unit control.
•
Note: Change factory setting only in exceptional cases and only with the consent
of the manufacturer.
P 2 Language setting
Use button
A
(
▲
) to change to parameter langu-
age setting
P 2
. Now press button
B
▲
and the
control unit will change to input mode.
You can now use buttons
A
(
▲
and
▼
) to select
the language required. Press button
B
▲
again
to accept the language selected.
Then press the „Mode button“ (
M
) for at least
2 seconds. The parameters will be saved and
the menu will close. The Display switches into
operating mode.
A
A
B
Switches to the control unit parameter menu.
Button for switching the unit on or off or swit-
ching to menu management.
Can be used to increase or reduce the set-point
temperature in the status display or to switch
through the individual operating menus or ope-
rating parameters.
Can be used to increase or reduce the fan
stages in the status display or to set values in
the individual operating menus or operating
parameters.
0 DEUTSCH
0 DEUTSCH
1 ENGLISH
2 FRANCAIS
3 DANSK
4 ESPAÑOL
5 NEDERLANDS
6 PORTUGUÊS
7 POLSKI
8
9
Содержание RLI 1200 EC
Страница 31: ...English www ruck eu 31 15 2 Wiring diagrams RLI 700 FC Wiring diagrams No 119820 Part 1...
Страница 33: ...English www ruck eu 33 RLI 700 FC Wiring diagrams No 119820 Part 4 RLI 700 FC Wiring diagrams No 119820 Part 5...
Страница 35: ...English www ruck eu 35 RLI 700 EC Wiring diagrams No 123344 Part 2...
Страница 36: ...English Tel 49 7930 9211 0 Fax 49 7930 9211 150 36 RLI 900 FC Wiring diagrams No 118155 Part 1...
Страница 37: ...English www ruck eu 37 RLI 900 FC Wiring diagrams No 118155 Part 2 RLI 900 FC Wiring diagrams No 118155 Part 3...
Страница 39: ...English www ruck eu 39 RLI 1200 FC Wiring diagrams No 119819 Part 1...
Страница 42: ...English Tel 49 7930 9211 0 Fax 49 7930 9211 150 42 RLI 1200 EC Wiring diagrams No 120618 Part 1...
Страница 44: ...English Tel 49 7930 9211 0 Fax 49 7930 9211 150 44 RLI 1200 EC Wiring diagrams No 120618 Part 4...
Страница 45: ...English www ruck eu 45 RLI 1600 FC Wiring diagrams No 120619 Part 1...
Страница 48: ...English Tel 49 7930 9211 0 Fax 49 7930 9211 150 48 RLI 1600 EC Wiring diagrams No 120622 Part 1...
Страница 50: ...English Tel 49 7930 9211 0 Fax 49 7930 9211 150 50 RLI 1600 EC Wiring diagrams No 120622 Part 4...
Страница 51: ...English www ruck eu 51 RLI 2000 FC Wiring diagrams No 120625 Part 1...
Страница 54: ...English Tel 49 7930 9211 0 Fax 49 7930 9211 150 54 RLI 2000 EC Wiring diagrams No 120626 Part 1...
Страница 56: ...English Tel 49 7930 9211 0 Fax 49 7930 9211 150 56 RLI 2000 EC Wiring diagrams No 120626 Part 4...
Страница 57: ...English www ruck eu 57 Notes...