background image

9

2015

2015

2015

2015

2015

2015

53,1

58

56,5

61,4

52,6

56,9

A

A

A

A

A

A

statisch

statisch

statisch

statisch

statisch

statisch

68,7

71,7

68,3

71

70

72,4

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

0,33

0,49

0,77

1,23

0,22

0,34

1233

1771

2179

3128

1686

2331

478

555

700

860

232

280

2915

2862

2761

2838

1478

1467

DVNI 225 D2 F4 30

DVNI 250 D2 F4 30

DVNI 280 D2 F4 30

DVNI 315 D2 F4 30

DVNI 315 D4 F4 30

DVNI 355 D4 F4 30

144615

144616

144617

144618

144619

144620

2015

2015

2015

2015

2015

2015

58,2

63,4

63,7

63,25

66,6

62,1

A

A

A

A

A

A

statisch

statisch

statisch

statisch

statisch

statisch

71,7

74

72,3

69,4

69,9

68

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

nicht integ-

riert / muss 

installiert 

werden!

0,51

0,97

1,51

2,59

4,81

2,75

2988

4565

5879

8551

12322

11278

340

476

576

686

953

541

1450

1468

1450

1436

1449

984

DVNI 400 D4 F4 30

DVNI 450 D4 F4 30

DVNI 500 D4 F4 30

DVNI 560 D4 F4 30

DVNI 630 D4 F4 30

DVNI 710 D6 F4 30

144621

144622

144623

144624

144625

144626

EN

9.  DATA IN ACCORDANCE WITH ERP DIRECTIVE 327/2011 OF THE EUROPEAN PARLIAMENT

ErP-conformity

1

Overall efficiency   η

es

 [%]

2

Measurement category

3

Efficiency category

4

Efficiency grade at optimum energy efficiency point   N

5

Variable speed drive

6

Year of manufacture

7

Manufacturer name / Commercial registration number / Place of establishment

8

Nominal motor power input at optimum energy efficiency point   P

e

 [kW]

9

Volumetric flow at optimum energy efficiency point   q

V

 [m³/h]

10

Static pressure at optimum energy efficiency point   p

sf

 [Pa]

11

Rotations per minute at the optimum energy efficiency point   n [1/min]

12

The specific ratio

13

Information on dismantling, recycling and disposal

14

Optimal life

15

Description of additional items used when determining the fan ener-

gy efficiency, such as ducts, that are not described in the measure-

ment category and not supplied with the fan.

Units / Model

ID-number

see nameplate 

ruck Ventilatoren GmbH / Local District Court Mannheim HRB 560367 / Germany

The specific ratio is close to 1 and significantly below 1.11.
Observe the user manual of this product.
Observe the user manual of this product.

No special items have been used for determining the fan energy effi-

ciency, except the required connection components according to the 

measurement category.

Units / Model

ID-number

see nameplate 

ruck Ventilatoren GmbH / Local District Court Mannheim HRB 560367 / Germany

ErP-conformity

1

Overall efficiency   η

es

 [%]

2

Measurement category

3

Efficiency category

4

Efficiency grade at optimum energy efficiency point   N

5

Variable speed drive

6

Year of manufacture

7

Manufacturer name / Commercial registration number / Place of establishment

8

Nominal motor power input at optimum energy efficiency point   P

e

 [kW]

9

Volumetric flow at optimum energy efficiency point   q

V

 [m³/h]

10

Static pressure at optimum energy efficiency point   p

sf

 [Pa]

11

Rotations per minute at the optimum energy efficiency point   n [1/min]

12

The specific ratio

13

Information on dismantling, recycling and disposal

14

Optimal life

15

Description of additional items used when determining the fan ener-

gy efficiency, such as ducts, that are not described in the measure-

ment category and not supplied with the fan.

The specific ratio is close to 1 and significantly below 1.11.
Observe the user manual of this product.
Observe the user manual of this product.

No special items have been used for determining the fan energy effi-

ciency, except the required connection components according to the 

measurement category.

Static

Static

Static

Static

Static

Static

Static

Static

Static

Static

Static

Static

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

not integra-

ted / has to 

be instal-

led !

www.ruck.eu  |  

Содержание DVN***D.F4 Series

Страница 1: ...OPEAN PARLIAMENT 9 10 TRANSPORT AND STORAGE 10 11 ASSEMBLY 10 12 ELECTRICAL CONNECTION 13 13 COMMISSIONING 15 14 MAINTENANCE AND CLEANING 16 15 LIFETIME AND DISPOSAL 18 16 TROUBLESHOOTING 18 ruck Vent...

Страница 2: ...bleshooting of the product The product has been manufactured according to the accepted rules of current technology There is however still a danger of personal injury or damage to equipment if the foll...

Страница 3: ...re 3 GENERAL SAFETY INSTRUCTIONS Planners plant engineers and operators are responsible for ensuring that the product is installed and operated correc tly Use our devices only in perfect technical con...

Страница 4: ...tructions before the steps whenever there is a danger of personal injury or damage to the equipment The measures described to avoid these hazards must be observed Safety instructions are set out as fo...

Страница 5: ...Before performing any work on conductive parts al ways disconnect the unit completely from the electri city supply and make sure that it cannot be switched back on again Never reach into the impeller...

Страница 6: ...ed to operate the setting mechanisms of the components or parts under the provision that the system is used as intended In an emergency or if there is a fault or other irregularities switch the equipm...

Страница 7: ...P 2015 Catalog item number Test date CE mark Grounding Series perm temperature time in smoke extraction perm temperature in continuous operation DVN D F4 400 C 120 min 20 C bis 200 C DVNI D F4 400 C 1...

Страница 8: ...8 5 50 200 91 86 146916 163 0 DVNI 710 D6 F4 30 144626 400V 3 Y 50 2768 6 9 50 200 83 143654 144615 534 467 363 341 484 556 245 4x 9 213 6x M6x15 144616 534 467 363 341 484 556 245 4x 9 213 6x M6x15 1...

Страница 9: ...etermining the fan ener gy efficiency such as ducts that are not described in the measure ment category and not supplied with the fan Units Model ID number see nameplate ruck Ventilatoren GmbH Local D...

Страница 10: ...ion If moisture has penetrated into the original packaging remove it immediately Storage temperature between 5 C and 40 C Avoid severe temperature fluctuations If the product has been in storage for m...

Страница 11: ...e nozzle plate 4 with hexagonal screws and sealing washers 5 6 on roof socket DSF If required it is possible to install further accessories at this point see 11 3 Installation examples with accesso ri...

Страница 12: ...26383 DVNI D F4 EN Installation operating and maintenance instructions 11 3 Installation examples DSF DAS DAF Tube Roof fan DSF Tube DSF DAS DAF Tube Roof fan DVK DSF DVK DAS DAF Tube Roof fan DSF DVK...

Страница 13: ...g between the unit and the duct system Check all protective measures after the electrical connection work earthing resistance etc Motor current and motor power must not exceed the values stated on the...

Страница 14: ...e time For the delta circuit the shorting blades are connecting U1 with W2 V1 with U2 and W1 with V2 see Img Never connect both jumpers at the same time If in spite of the correct connection to the ma...

Страница 15: ...lectric motors heat up Under certain circumstances excessively high ambient or fluid temperatu res heavy contamination etc the motor temperature may exceed the safety limit of the electrically isolate...

Страница 16: ...6 months Check impeller rotation direction yearly Check flexible connections for leaks yearly Check impeller for imbalance yearly Check protective device for function yearly Motor Check externally for...

Страница 17: ...all the threaded studs 3 and screw them out completely Lubricate a threaded pin and screw it into the disassembly hole 4 2 Tighten the threaded pin until the clamping bush 1 is released from the hub...

Страница 18: ...given here depends strongly on the respective field of application as well as the environmental condi tions We recommend replacing these fans after reaching about 30 000 operating hours or 5 years Fa...

Страница 19: ...19 EN Notes www ruck eu...

Страница 20: ...nt 25 02 2019 mdnif_pb_05_en We reserve the right to make changes Language English ruck Ventilatoren GmbH Max Planck Str 5 D 97944 Boxberg Windischbuch Tel 49 0 7930 9211 300 Fax 49 0 7930 9211 166 in...