23 — English
WARNING:
When servicing, use only identical replacement
parts. Use of any other parts can create a hazard
or cause product damage.
WARNING:
Always wear eye protection with side shields
marked to comply with ANSI Z87.1 during product
operation. If operation is dusty, also wear a dust
mask.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline,
petroleum-based products, penetrating oils, etc.,
come in contact with plastic parts. Chemicals can
damage, weaken or destroy plastic which can
result in serious personal injury.
LUBRICATION
All of the bearings in this tool are lubricated with a sufficient
amount of high grade lubricant for the life of the unit under
normal operating conditions. After extended use, clean the
rails so the table will slide smoothly.
CLEANING THE RAILS
During use, the rails will become dirty preventing the table
rollers from sliding smoothly. It is important to clean the
rails often.
MAINTENANCE
CLEANING THE SAW
Unplug the saw.
Using a small brush and/or water, clean each piece thor-
oughly removing any trapped debris.
Remove the drain and empty waste water into a bucket.
Do not allow the water to splash onto the ground or around
the machine.
Rinse the machine thoroughly.
Discard the waste water in accordance with local regula-
tions.
Replace the drain plug. Tighten securely.
Dry off the tool.
CLEANING THE PUMP
For best performance, the pump may be cleaned periodi-
cally.
Unplug pump before handling or cleaning the pump.
Remove the front cover.
Using a small brush and/or water, clean any debris or
trash that is trapped on the inside of the pump.
Replace the front cover.
NOTE:
To maintain efficiency and extend the life of the
pump, check intake screen before use to make sure it is
clean.
If the pump will not run, try the following solutions:
Ensure that the intake screen is free of obstructions.
Make sure that the water hose isn’t clogged or knotted.
Be sure the unit is plugged into a functioning power outlet.
NOTE:
To prevent accidental starting, do not handle the
pump while it is connected to a power source.
Содержание DT180EVO