8 | Instruments (Display Modes) | 8.6 | The RTA 1/3 and RTA 1/6 Instruments
EN-78
SurroundControl 31900/31960 Series
First function layer
• Display
Hold
(First layer, button/key 1)
Selecting this function freezes the RTA display. A cursor
readout of all frequency bands is possible. The buttons/
keys
REF+
and
REF–
are disabled. This button/key has
toggle function – select again to turn off
Display Hold
.
•
< Cur and Cur >
(First layer, button/key 2 and button/key 4)
These functions move the cursor to the previous or next
frequency band in the RTA. You can also move the cursor
to the left and right by clicking and dragging with the opti-
onal mouse.
• Cur
Ref
(First layer, button/key 3)
Selecting this function sets the current layer of the se-
lected frequency band as the reference value. If you then
set the cursor on another band the difference between
this band and the reference value is shown in the cursor
readout.
•
REF+ and REF–
(First layer, button/key 5 and button/key 6)
These functions enable you to shift the display’s reference
point for a clearer readout in the window. The RTA’s layer
display is always relative.
• Scale
(First layer, button/key 7)
This function switches the display scale between
3
,
6
and
9
dB divisions.
Second function layer (select MORE to activate)
• Range
(Second layer, button/key 1)
This function switches the frequency range of the RTA
display between
LF
(5 Hz – 5 kHz) and
Norm
(20 Hz –
20 kHz).
• Weighting
(Second layer, button/key 2)
This function allows you to select weighting fi lter
A
or
C
.
Selecting
lin
(linear) deactivates the weighting fi lters.
• RMS
(Second layer, button/key 3)
This function (toggle function linked to button/key 5 –
Peak
) changes the integration time of the RTA display’s
RMS detector, as follows:
•
I:
Impulse (35 ms)
•
S: Slow (1000 ms)
•
F: Fast (125 ms, corresponds to IEC standard)
• Peak
(Second layer, button/key 4)
This function (toggle function linked to button/key 4 –
RMS
) switches the display between peak integration with
10 ms and RMS integration.
• PHold
(Second layer, button/key 5)
This function switches the peak hold display
on
or
off
.
• PHold
Reset
(Second layer, button/key 6)
This function clears the longterm memory, the peak hold
memory and any stored digital errors.
Содержание SurroundControl 31960 Series
Страница 1: ...SurroundControl 31960 Manual...
Страница 2: ...SurroundControl 31960...
Страница 3: ...DE SurroundControl 31960 Serie Bedienungsanleitung...
Страница 12: ...Inhaltsverzeichnis DE 10 SurroundControl 31960 Serie...
Страница 38: ...6 Erste Schritte 6 13 Loudness Anzeigeoptionen verwenden DE 36 SurroundControl 31900 31960 Serie...
Страница 54: ...7 Steuerung 7 3 Extern ber die GP IO Schnittstelle steuern DE 52 SurroundControl 31900 31960 Serie...
Страница 217: ...EN SurroundControl 31960 Series Operating Manual...
Страница 226: ...Content EN 10 SurroundControl 31960 Series...
Страница 252: ...6 First Use 6 13 Using Loudness Display Options EN 36 SurroundControl 31900 31960 Series...
Страница 268: ...7 Control 7 3 External control via GP IO connector EN 52 SurroundControl 31900 31960 Series...