RTi-QAT Quality Air Test Kit w/ Digital Hygrometer

Rev. 9/2017

 
  

Proper Hookup for Testing Membrane Units 

 
 

 

Membrane units sold in the market have not been able to keep up with the air used when spraying 
paint. Because of this we are recommending doing the compressed air humidity test like this: 

1.

 

When testing membrane drying units you should use this setup to test Compressed Air 
Humidity.  

2.

 

Set the pressure on the QAT regulator @ 

50 PSI

3.

 

Hook the spray gun as shown and have the pressure on the gun set at what the painter uses to 
spray most of their paint finishes. 

4.

 

Pull the trigger on the gun and check the reading on the digital read out as the air is flowing 
through the gun. 

5.

 

Watch reading until it quits moving. Paint Companies want less than 10% on solvent and less 
than 3% on waterborne finishes 

This reading will give you an accurate reading of Compressed Air Humidity produced while spraying 
paint.  

Most units we have tested in the field range between 5

15% suppression from incoming Compressed Air 

Humidity into the membrane dryer. Average shop readings are around 38%, meaning these units are not 
performing to meet Paint Company Specs. 

ALL FINISHES  PERFORM BEST @ 0

3% COMPRESSED AIR HUMIDITY 

PROPER HOOKUP FOR TESTING MEMBRANE UNITS 

Membrane units sold in the market have not been able to keep up with the air used when spraying paint. Because of 

this we are recommending doing the compressed air humidity test. Refer to the previous pages on how to test.

This reading will give you an accurate reading of compressed air humidity that is produced while spraying paint.

Most units we have tested in the field range from 5-15% suppression from incoming CAH into the membrane dryer. 

Average shop reading are around 38%, meaning these units are not performing to meet paint company specifications.

Содержание QAT

Страница 1: ...read the gauge make a note of the reading 3 Air pressure drop from the compressed air source to the point of use Subtract the dynamic reading from the static reading The total is the pressure drop fro...

Страница 2: ...oblem Testing takes only minutes but can prevent or solve contamination problems which could cost thousands of dollars TO TEST FOR CONTAMINATION 1 Clean Housing Look into housing assembly and air pass...

Страница 3: ...y number and compare to paint company specifications Humidity needs to be below 10 for solvent and below 4 for water at 50 PSI EXAMPLE OF TESTING PROCEDURE The below list is a sample of readings and p...

Страница 4: ...ng sign on battery compartment and turn on LED lamp F Rotate battery cover clockwise aim the arrow on battery cover at the ultraviolet currency detecting sign on battery compartment and turn on LED ul...

Страница 5: ...igerated Dryer Filter Elements Desiccant Dryers Gun Filters Drained Y N circle one How Often Date of Last Change How Often Date of Last Change How Often Date of Last Change How Often Y N Y N Y N Y N B...

Страница 6: ...www driair com www rti pbe com 800 521 9200 RTiPBE rti_pbe RTi QAT Quality Air Test Kit w Digital Hygrometer Rev 9 2017...

Страница 7: ...h the gun 5 Watch reading until it quits moving Paint Companies want less than 10 on solvent and le than 3 on waterborne finishes This reading will give you an accurate reading of Compressed Air Humid...

Отзывы: