RTi-QAT Quality Air Test Kit w/ Digital Hygrometer

Rev. 9/2017

UNIVERSAL CLIP-TYPE LED CELLPHONE MICROSCOPE

INSTALLATION AND USE OF UNIVERSAL CLIP-TYPE MICROSCOPE:

  1.  Clip universal clip-type microscope onto cellphone, move microscope eye lens to aim at camera lens on

      cellphone back, then fix them.

  2.  Open cellphone and bring up camera app, enlarge or shrink pictures to appropriate size, then pull focusing

      barrel up and down until the clearest images are obtained.

  3.  Rotate the threaded end of microscope eye lens counter-clockwise to dismantle microscope for separate use.

OPERATING INSTRUCTION OF MICROSCOPE:

  1.  Put sample on a flat surface.

  2.  Place microscope vertically with object lens (B) facing downwards.

  3.  In time of insufficient light, rotate battery cover (D) counter-clockwise, aim the arrow on battery cover at the

      lighting sign on battery compartment, and turn on LED lamp (F). Rotate battery cover clockwise, aim the arrow on

      battery cover at the ultraviolet currency detecting sign on battery compartment, and turn on LED ultraviolet lamp.

      Rotate battery cover arrow to aim at closing sign on battery compartment, then turn off LED lamp.

  4.  View objects through eye lens (A).

  5.  If images are not clear, pull focusing barrel (C) up and down until the clearest images are obtained.

REPLACEMENT OF BATTERIES:

  1.  Rotate the arrow sign on battery cover counter-clockwise to aim at the dot sign (●) on battery compartment, then

      open battery cover (D). 

  2.  Take three old LR1130 batteries from battery compartment (E), then put three new LR1130 batteries inside,

      with anode facing upwards and cathode downwards.

  3.  Aim the arrow sign on battery cover at the dot sign (●) on battery compartment, then press battery cover slightly,

      and rotate it clockwise to closing sign to close battery cover.

Cellphone Universal Clip

Battery Cover (D)

Eye Lens (A)

Focusing Barrel (C)

Object Lens (B)

LED Lighting/LED Currency Detecting Lamp (F)

Battery Compartment (E)

Содержание QAT

Страница 1: ...read the gauge make a note of the reading 3 Air pressure drop from the compressed air source to the point of use Subtract the dynamic reading from the static reading The total is the pressure drop fro...

Страница 2: ...oblem Testing takes only minutes but can prevent or solve contamination problems which could cost thousands of dollars TO TEST FOR CONTAMINATION 1 Clean Housing Look into housing assembly and air pass...

Страница 3: ...y number and compare to paint company specifications Humidity needs to be below 10 for solvent and below 4 for water at 50 PSI EXAMPLE OF TESTING PROCEDURE The below list is a sample of readings and p...

Страница 4: ...ng sign on battery compartment and turn on LED lamp F Rotate battery cover clockwise aim the arrow on battery cover at the ultraviolet currency detecting sign on battery compartment and turn on LED ul...

Страница 5: ...igerated Dryer Filter Elements Desiccant Dryers Gun Filters Drained Y N circle one How Often Date of Last Change How Often Date of Last Change How Often Date of Last Change How Often Y N Y N Y N Y N B...

Страница 6: ...www driair com www rti pbe com 800 521 9200 RTiPBE rti_pbe RTi QAT Quality Air Test Kit w Digital Hygrometer Rev 9 2017...

Страница 7: ...h the gun 5 Watch reading until it quits moving Paint Companies want less than 10 on solvent and le than 3 on waterborne finishes This reading will give you an accurate reading of Compressed Air Humid...

Отзывы: