background image

www.driair.com | www.rti-pbe.com

(800) 521-9200

@RTiPBE

@rti_pbe

RTi-QAT Quality Air Test Kit w/ Digital Hygrometer

Rev. 9/2017

HUMIDITY TESTING PROCEDURE 

 

1.  Adjust pressure to the tester to 50 PSI.

  2.  Set tester to dew point (once on, push ON button twice).

  3.  Use phone app (Calculator of Air for iPhone, or Michell Instruments for Android) to convert dew point into paint

      company standard (or 70°F) air temperature.

  4.  In phone app, enter 70°F for temperature on the tester and insert dew point number from the tester and hit the

      equals (=) sign to obtain the compressed air humidity (CAH) number. If app is not available, use attached Wet

      Bulb chart to find CAH.

  5.  Record humidity number and compare to paint company specifications.

Humidity needs to be below 10% for solvent and below 4% for water at 50 PSI.

EXAMPLE OF TESTING PROCEDURE

  The below list is a sample of readings and procedures that is used to find the CAH in your airlines using our QAT kit.

  1.  Plug in tester.

  2.  Set pressure at 50 PSI.

  3.  Run until stabilizes.

  4.  Measure dew point from tester: (41°F)

  5.  Go to app, input 70°F  to comply with paint company

      standards and enter the dew point and hit enter to

      calculate humidity (write it down).

  6.  If phone app is not available, use attached Wet

      Bulb chart to figure humidity at 70°F.

  7.   Enter humidity reading from app or Wet Bulb data

      from chart to get actual humidity: 

      24.96% CAH in air lines.

Below is an example of the “Calculator of Air” 

app available for iPhone

Below is an example of the “Michell Instruments” 

app available for Android

Содержание QAT

Страница 1: ...read the gauge make a note of the reading 3 Air pressure drop from the compressed air source to the point of use Subtract the dynamic reading from the static reading The total is the pressure drop fro...

Страница 2: ...oblem Testing takes only minutes but can prevent or solve contamination problems which could cost thousands of dollars TO TEST FOR CONTAMINATION 1 Clean Housing Look into housing assembly and air pass...

Страница 3: ...y number and compare to paint company specifications Humidity needs to be below 10 for solvent and below 4 for water at 50 PSI EXAMPLE OF TESTING PROCEDURE The below list is a sample of readings and p...

Страница 4: ...ng sign on battery compartment and turn on LED lamp F Rotate battery cover clockwise aim the arrow on battery cover at the ultraviolet currency detecting sign on battery compartment and turn on LED ul...

Страница 5: ...igerated Dryer Filter Elements Desiccant Dryers Gun Filters Drained Y N circle one How Often Date of Last Change How Often Date of Last Change How Often Date of Last Change How Often Y N Y N Y N Y N B...

Страница 6: ...www driair com www rti pbe com 800 521 9200 RTiPBE rti_pbe RTi QAT Quality Air Test Kit w Digital Hygrometer Rev 9 2017...

Страница 7: ...h the gun 5 Watch reading until it quits moving Paint Companies want less than 10 on solvent and le than 3 on waterborne finishes This reading will give you an accurate reading of Compressed Air Humid...