7
Technical Manual - RVL-N Single Wire Loop Box v16.5.2014
www.repo.eu
Wire rope loop
Design value for shear force in one pair
of wire rope loops (one wire rope loop on
each side of the joint) VRd [kN]
RVL-60N
11.7
RVL-80N
11.7
RVL-100N
11.1
RVL-120N
9.6
RVL-140N
8.5
Design values of resistance presented in the table 3 are resistances in ultimate limit state with given
center to center distances of RVL wire rope loop boxes. Values are given as kN/m. The minimum concrete
strength in the joint (element/joint concrete) is C25/30 (cylinder strength 25 MPa, cube strength 30 MPa).
V
rd
[kN/m]
c/c
[mm]
RVL-60N
RVL-80N
RVL-100N RVL-120N RVL-140N
250
46.8
46.8
44.3
38.4
33.9
300
39.0
39.0
36.9
32.0
28.2
350
33.4
33.4
31.6
27.4
24.2
400
29.3
29.3
27.7
24.0
21.2
450
26.0
26.0
24.6
21.3
18.8
500
23.4
23.4
22.2
19.2
16.9
550
21.3
21.3
20.1
17.5
15.4
600
19.5
19.5
18.5
16.0
14.1
650
18.0
18.0
17.0
14.8
13.0
700
16.7
16.7
15.8
13.7
12.1
750
15.6
15.6
14.8
12.8
11.3
7
tAblE 2
| DesigN VaLUe oF ResistaNce FoR LoNgitUDiNaL sHeaR
FoRce iN oNe paiR oF wiRe Rope Loops
tAblE 3
|
DesigN VaLUes oF ResistaNce FoR LoNgitUDiNaL sHeaR
FoRce FoR wiRe Rope Loops