OPEL 2000
20
3. BEFORE fastening the controls with the 2 screws
provided, thread the supplied chain through the spare
keyhole in the draft control and attach a pendant to the
end, just like the chain that is beside it. Let the chain
down on the same side of the heat shield as the existing
chain, and attach it to the lever on the damper motor
with another pendant. Push the pendant snug into the
hole in the lever. Then mount the controls to the bracket.
4. Adjust the chain on the draft control lever until it is
just snug but the damper is still closed. When the
damper motor is energized, the damper should open all
the way. Lock the chain onto the keyhole with another
pendant just like the chain beside it.
5. Wire the thermostat as shown in figure 15, making
sure the wall control is sufficiently away from the direct
radiation of the fireplace. Make certain that it is at least
10 ft. away from the fireplace, but in the same room.
CIRCULATING BLOWER (FD-HB5-N)
NOTE: It is important that the wiring for the blower kit is
installed during framing so that the wiring can be easily
hidden.
1. Remove the bottom louver. It is held in place by springs
underneath. Therefore, push down from the top, then
rotate and pull forward.
2. Hold the blower with the outlet facing up from the
back. Fit the blower through the louver opening.
3. Slide the blower into place between the two brackets
4. Mount the thermal switch as shown in figure 17. The
front face of the fireplace is bent into a flange just above
the lower opening. It has holes to hold the bottom louver
rods. The thermal switch mounts just to the left of the
Figure 16: Circulating blower
circulating blower
thermal switch bypass
terminal block
blower speed control
thermodisc
See wiring diagram
Figure 35
Figure 17: Circulating blower location (sectional view)
circulating blower
terminal block
mounting clips
thermal switch
louvre retention spring
bottom louvre
Содержание OPEL 2000
Страница 40: ...OPEL 2000 40 ...