15
Output Summary
RSPD3303C is designed with three independent outputs, two of
which are adjustable in voltage value and the other includes a set of
selectable voltage values: 2.5V, 3.3V or 5.0V.
Independent/Parallel/Series
RSPD3303C has three output modes: independent, parallel and
series that could be selected through the track switch on the front
panel. In independent mode, the output current and voltage are
controlled respectively. In parallel mode, the current value is twice
that of single channel. In the series mode, the voltage value is twice
that of single channel.
Constant Current/Voltage
In constant current mode (series/track mode), the current value is rated.
When the voltage value are under its rating, the indicator light displays
red. The instrument will automatically return to constant voltage mode
when the current value is under rated. In parallel 1 mode, the accessory
channel remains in constant current mode neglecting shift of the current
value.
In constant voltage mode, the voltage value is rated. When the current
value are under its rating, the indicator light dispays green.
The instrument will turn to constant current mode when the current
value returns to its rating.