background image

27

Track Isolators, 4 required. 

TO TURNOUTS
wired in parallel

 Switch RED relay Terminals

 Switch GREEN relay Terminals

li

a

R

 t

f

e

late  L

so

d

 I

o

t

 

h

c

a

t

t

A

Alternating Trains at a Siding, AC or DC Trains

Trains will ALTERNATE without stopping with powered turnouts.

This hookup will allow two trains to alternate. When one train enters a siding it will hit a sensor and cause the 
YardMaster to switch power to the other siding.  There will be no pause, just an exchange of the running train.

Both turnouts are wired in parallel and attached to the TURNOUT terminals of the YardMaster. The exiting turnout can be 
powered or non-powered. (one direction only. For two directions both turnouts must be powered)

The YardMaster will switch when the train is clear of the sensor. This will prevent the train from parking on the sensor. 

The sensors have no polarity. See the power page for input power requirements.

If acceleration, deceleration, or station pause is desired consider using a StationMaster instead of  this hookup. 

Enhancement Ideas: 
1. Program a lap count for each train to do multiple laps  before switching.
2. Add a signal light

1

2

3

4

5

6

20

19

18

17

16

15

7

11

8

12

9

13

14

A

li

tta

a

ch 

t R

to Isolated Lef

Sensors
at stopping
position
wired in
PARALLEL

Trains can run in either direction.

 RRConcepts.com

From transformer
ACCESSORIES
or separate power
source

 Power Input

Parts List

YardMaster          1
Track Isolators     4
Train Sensor        2
Train magnet       2
wire as required

Attach to outside rail.
This line is switched between 20 and 18

Содержание YardMaster-5

Страница 1: ...o Detachable screw down terminal blocks allow quick disconnect for long term storage keeping all wires in place ONLY ATTACH WIRES WHILE THE POWER IS OFF YardMaster 5 Turnout Track switch Controller La...

Страница 2: ...ht connections 8 Factory Reset 9 Operating Modes 10 Time Delay 11 ID number 12 Laps 13 Forced Alternate 14 Auxiliary Relay Module 15 STOP GO Relay Modue Descriptions 16 Block Control 17 Station Stop 1...

Страница 3: ...Switch GREEN relay Terminals and Switch RED will cause the Common Relay Terminals to connect to the Switch RED Terminals The TURNOUT will also fire in synchronization and the lamps outputs will change...

Страница 4: ...The connecting plugs are keyed for correct orientation The tab on the plug will be on the top when attached correctly If the center wire is cut the StationMaster will only provide power to the YardMa...

Страница 5: ...voltage Except for the 5 volt LED output which is constant ALSO IMPORTANT When turnouts are attached the AMPERAGE must be sufficient to power them without a voltage drop which would reset the YadMast...

Страница 6: ...le a 12VAC input will provide approximately 16VDC turnout voltage etc If a short circuit condition is present on these terminals the YardMaster will blink the BLUE LEDs when energized After a delay th...

Страница 7: ...to terminal 18 Terminal 4 will internally connect to terminal 17 The Alternate sensor or alternate pushbutton will alternate these contacts Since this is a simple relay there are no polarity or voltag...

Страница 8: ...feature can be turned off if needed by programming a different operating mode If direct driving LED s use pin 14 as the constant 5 volt voltage source and wire as shown for either separate LEDs or a...

Страница 9: ...seconds YardMaster will slowly flash the blue sensor LED many times but keep holding down the button After a delay the blue status LED will twinkle to indicate a factory reset Release the button Facto...

Страница 10: ...is the default setting after a factory reset 2 Control SLOW_MOTION turnouts electric switches These include Tortoise Aristocraft slow motion etc 3 Synchronize Auxiliary relay to internal relay Can not...

Страница 11: ...time delay will not be operational when attached to a StationMaster 2 To clear the time delay either program for 1 blink or perform a factory reset Programming a Time Delay Used for Station stops Reve...

Страница 12: ...ogram as YardMaster 4 4 IDs are possible to allow 4 YardMasters to be wired together 3 Quickly press the ALTERNATE pushbutton to exit programming mode Notes 1 Unless programmed for an ID other than 1...

Страница 13: ...3 blinks 3 laps 4 blinks 4 laps 3 Quickly press the ALTERNATE pushbutton to exit programming mode Notes 1 The lap counter will not function when attached to a StationMaster 2 When attached to a Stati...

Страница 14: ...sor is hit For example when the Switch RED sensor is hit the Alternate sensor will always switch to GREEN regardless of the number of times it is hit This allows the turnout to be set correctly for op...

Страница 15: ...ndle A very quick burst of voltage is given to the switch motor which prevents overheating and operates without the need for capacitive discharge units When the YardMaster is programmed for blink 3 th...

Страница 16: ...etected When an ALTERNATE sensor is triggered the relay will energize for the programmed time delay and then the alternate function will occur This allows a time delay station stop When the FORCE RED...

Страница 17: ...ith the switch GREEN sensor location to obtain the desired results The signal light is optional but adds to the fun Switch Green Sensor Switch RED Sensor Green Terminal Optional Signal Light Block Con...

Страница 18: ...nate button This is a one time operation since the YardMaster will remember the switch state in memory Change the direction of the train as required The YardMaster will operate in both directions Addi...

Страница 19: ...one time operation since the YardMaster will remember the switch state in memory Change direction of the train as required The YardMaster will operate in both directions Terminals 3 4 connect to the A...

Страница 20: ...to GREEN The train will stop After the programmed time delay the YardMaster will switch to RED and the train will run again Change direction of the train as required The YardMaster will operate in bo...

Страница 21: ...celerations consider using a StationMaster for a station stop DC trains only Station Stop Hookup Diagram for a Remote Track Section Track power provides power to YardMaster This is basically the same...

Страница 22: ...aster for a station stop Station Stop Hookup Diagram for a Remote Track Section Place MAGNET on bottom of engine Track power provides power to YardMaster Isolators 2 places Station Stop with Sensors T...

Страница 23: ...ce the points to the correct orientation not shown Magnets are not offset but placed as normal As the train passes over a sensor the turnout aligns to the proper orientation The Smart Turnout works fo...

Страница 24: ...on the same track The Alternating Path hookup will work for ALL trains Electric Battery and Live Steam See power hookup page for input power requirements For more fun the YardMaster can directly driv...

Страница 25: ...ggered the YardMaster will return to the Switch RED state and turn off the signal light Whatever power is applied to terminals 3 and 4 will be switched to terminals 19 and 20 when the YardMaster is GR...

Страница 26: ...or DC up to 110V Be careful The graphics on the module show the terminal connections Pin 1 Normally open pole 1 Pin 2 Switching pole 1 switches between 1 and 3 Pin 3 Normally closed pole 1 Pin 4 Norm...

Страница 27: ...irections both turnouts must be powered The YardMaster will switch when the train is clear of the sensor This will prevent the train from parking on the sensor The sensors have no polarity See the pow...

Страница 28: ...t the train from parking on the sensor The sensors have no polarity See the power page for input power requirements If acceleration and deceleration is desired DC trains only consider using a StationM...

Страница 29: ...instead of this hookup It is also a much easer hookup Enhancement Ideas 1 Program a lap count for each train to do multiple laps before switching 2 Add a signal light 1 2 3 4 5 6 20 19 18 17 16 15 7...

Страница 30: ...t Pin 19 is connected to pin 18 and these two are connected to the other DC transformer output Pins 8 and 9 are shorted together This tells the YardMaster to perform automatic switching using a progra...

Страница 31: ...ck and forth Automatic Reversing with in between station stops Diode with insulated rail connector One on each side RRConcepts com Red wire this end Attach relay cable between relay and YardMaster Add...

Страница 32: ...g diode Required Slow down diodes optional Slow down diodes optional To YardMaster Stopping block Stopping block Slowing block Slowing block Full speed block Alternatively diodes can be added directly...

Страница 33: ...Attach relay cable between relay and YardMaster Add additional sensors in parallel for additional stops STOP GO RELAY MODULE SIDING SELECTION RELAY MODULE Program for Single Siding blink 7 Jumper bet...

Страница 34: ...n station stops OPTION No track modifications RRConcepts com No jumper When it is not desirable to add diodes to the track for end of track sensing an alternative is to add sensors as shown Sensors ar...

Страница 35: ...al terms PORT IS POSITIVE For LGB style trains the left rail is always POSITIVE while the right rail is NEGATIVE Notice that this is reversed for trains following NMRA standards such as HO N etc and t...

Страница 36: ...ED and GREEN buttons on the YardMaster Swap the wires in the turnouts as necessary to make this happen Notice that the sensors must be 100 reliable or a short circuit will occur For some commercial ap...

Страница 37: ...A voltmeter could be used to test this left rail is positive for G scale or quickly place a train on the track to see which way it wants to go but don t let it enter the loop yet Reverse the wires to...

Страница 38: ...ns of the trains are as shown For large scale trains in nautical terms PORT IS POSITIVE For LGB style trains the left rail is always POSITIVE while the right rail is NEGATIVE Notice that this is rever...

Страница 39: ...en a sensor is triggered track power will switch to the other loop of track Note differences in terminals 3 4 5 and 6 between AC trains and DC trains AC trains generate electrical noise which affect t...

Страница 40: ...g RED or GREEN a time delay is in process When flashing RED BLUE and then GREEN BLUE the YardMaster is self running due to the RED sensor terminals closed on power up STATUS LED Sensor LED LED indicat...

Страница 41: ...gnet offset to the right and freight trains have the magnet offset to the left side Sensor placement for HO EZ track is under the roadbed Other scale trains can place the sensors where appropriate Ver...

Отзывы: