10
1. Make sure all three sensor inputs are open.
2. If the top speed dial is not already at zero, then turn the top speed dial to zero.
(fully counter-clockwise.) The sensor LED will turn ORANGE.
3. Push and hold programming button #1.
4. Watch the status led. Each RED blink will decelerate slower.
The fastest deceleration will be with one blink
.
(TRAIN Stops
sooner) Release the pushbutton when the desired number of blinks have occurred.
A typical number is 5. Repeat this procedure if you want a different value.
One blink corresponds to a 3 second deceleration rate. Each additional blink adds
1 second. For example, a blink count of 5 would result in a deceleration rate of
8 seconds.
When finished with all programming turn the top speed dial fully clockwise and
then turn down to a desired creeping or top speed if needed.
All programming values are stored in flash memory and are retained until
re-programmed.
Programming:
Deceleration Rate
Fully
counter
clockwise
RRConcepts.com