7.
Fundamental operating notes
7.1.
Switching on the appliance
The refrigerating unit is switched on and off by pressing
the STANDBY button (5).
1
2
3
4
5
Above the buttons there is a digital display of the cooling
regulator. This field shows the medium temperature and
any errors.
Before filling the drop-in refrigerated well and
display cases with food, please wait until the desired
temperature has been reached.
Button 1
UP - button
Defrosting can be started any time by pressing the UP-
Button for 3 seconds
Button 2
DOWN - button
The DOWN Button, among other functions, can
acknowledge an alarm
Button 3
LIGHTING
Switch for external lighting (if available)
Button 4
SET - button
While SET Button is pressed, the setpoint is indicated
Button 5
STANBY - button
With this Button the controller is switched to standby
mode. Pressing the Button a second time, restarts the unit
7.2.
Setting the temperature
The interior temperature is regulated by an electric temperature regulator. This is located underneath
the refrigerated well and is easily accessible.
On the service side the refrigerated well is set at a temperature of 38°F. Your desired temperature
can be set by holding down the SET button (4) and simultaneously pressing UP - button (1) for higher
temperatures or DOWN - button (2) for lower temperatures.
THE DESIRED VALUE CAN ONLY BE SET WITHIN A CERTAIN RANGE
IN ORDER TO PREVENT ANY OPERATING ERRORS.
After resetting the temperature some time needs to pass before the desired temperature has been
achieved. Please check the interior temperature a few hours afterwards with an exact thermometer
and reset the thermostat if needed.
Depending on the surrounding temperature and humidity, the interior temperature is not to be set too
low as this could lead to icing on exposed areas of the cooling element. This will interfere with the
cooling performance and with the continuous defrosting which has been set by your specialized dealer
for a certain interval.
7.3.
Manual defrosting
Defrosting can be started any time by pressing the UP - button for 3 seconds. During the process of
defrosting the respective LED is illuminated. The LED flashes if defrosting is requested, but may not
be started yet due to interlock conditions.
7.4.
Lighting
External lighting of the refrigerated well can be connected to the cooling regulator and is then switched
on and off by pressing button (3).