Valid from: April 2012 

Technical changes reserved 

Page 3 

DOC:  OM_VIAP Vienna Air Pans (12A) 

 

 

 

 

OPERATING AND MAINTENANCE 

 

 
 

1.  

Introduction  

 
1.1. 

Welcome 

 
With the purchase of this new refrigerating equipment you have decided on a product that combines 
the  highest  technical  demands  with  practical  service  comfort.  We  recommend  that  you  read  these 
operating and maintenance instructions carefully in order to become familiar with the product quickly.  
 
With the proper treatment you will enjoy this appliance for a long time.  Please keep these operating 
and maintenance instructions to consult in case any maintenance and repairs are needed.  
 
We wish you successful business and much pleasure with this appliance.   
 
1.2. 

Fundamental Safety Notes  

 

 

THE CONNECTIONS AND ANY TECHNICAL ADAPTATIONS ON THE 

REFRIGERATED EQUIPMENT ARE ONLY TO BE CARRIED OUT BY 

SPECIALISTS!  THIS IS ESPECIALLY VALID FOR ANY WORK ON THE 

COOLING TECHNOLOGY, ELECTRICAL INSTALLATION, WATER CONNECTION 

AND MECHANICAL WORK.  

ANY ADAPTATION IS TO BE AUTHORIZED BY THE MANUFACTURER! 

 

 

Those covers bearing a warning may only be opened by specialists! 

  The bottom and back panels are not to be cleaned by water jet.   

  Protective covers and devices may not be removed due to risk of injury! 

  The control system may only be opened by an expert. 

  Air  currents  near  the  refrigerating  unit  resulting  from  improperly  installed  ventilation  or  draughts 

are to be avoided, in order to ensure the efficient functioning of the refrigerating unit.  

 

The surrounding temperature may not exceed 75°F; the relative humidity may not exceed 
55% over a long period of time. 

  Due to risk of injury, sharp objects are not to be stored loosely in the refrigerating unit.  

  Any glass parts are to be treated with the necessary care in order to avoid injuries resulting from 

broken glass.   

  Components and operating equipment may only be replaced by original parts.  

 
 
1.3. 

Warranty and Liabilities 

 
Fundamentally, our "General terms of sale and delivery“ are valid. These are known to the operator 
upon the signing of the contract at the latest. Claims of warranty and liability for damage to persons 
and property are not possible, if they result from one or several of the following causes:  
 

  Improper use of the unit.  

  Improper assembling, starting up, operating and servicing of the unit.  

  Operating the unit with defective safety devices or safety devices which have not been installed 

properly and are not in working condition.  

  Disregard  of  the  references  in  the  operating  manual  concerning  transportation  storage, 

installation, start-up, operation, maintenance and assembling of the unit.  

  Unauthorized mechanical or electrical changes to the unit.  

  Insufficient maintenance of wear and tear parts.  

  Unauthorized repair. 

  Extreme environmental concern, fire, explosions etc.  

 
 
 
 
 

Содержание VIENNA Air Pan

Страница 1: ...g and Maintenance instructions Information in this manual has to be followed Please read it carefully before you start to operate your refrigeration well You can always ensure having a fully functiona...

Страница 2: ...notes 4 6 First Steps 5 Control of delivery 5 installation 5 Power plug finished devices 5 7 Fundamental operating notes 6 Switching on the appliance 6 Setting the temperature 6 Manual defrosting 7 Li...

Страница 3: ...rt Air currents near the refrigerating unit resulting from improperly installed ventilation or draughts are to be avoided in order to ensure the efficient functioning of the refrigerating unit The sur...

Страница 4: ...or your health and or can lead to property damages This symbol points to operation tips and especially useful information Helps you to use all functions on your unit optimally 1 5 Validity These opera...

Страница 5: ...s Any other uses beyond those intended are to be considered as not being in compliance with the regulations The manufacturer supplier is not liable for any damages resulting from such actions The user...

Страница 6: ...t up of the refrigerated unit Every installation has to fit to the local electric safety and hygiene instructions Please assemble the unit away from any heat sources or on any places where you will ha...

Страница 7: ...ible On the service side the refrigerated well is set at a temperature of 38 F Your desired temperature can be set by holding down the SET button 4 and simultaneously pressing UP button 1 for higher t...

Страница 8: ...he goods area through an discharge air duct 3 The airflow takes place via an angled ventilation plate 4 By exactly determining the components very even air distribution is obtained The Air Pans are eq...

Страница 9: ...RY H offers same features like BAKERY with raised air tower it is suitable for presenting larger products Loading height BAKERY H 32 4 inch BAKERY H 38 6 inch BAKERY DIFF 5 inch FOODSTATION 4 inch Mod...

Страница 10: ...er residue on these parts It is absolutely necessary to bear some fundamental things in mind to keep this stainless steel unit working and to maintain its long life always keep the stainless steel sur...

Страница 11: ...eaning After cleaning lift the evaporator remove the lock and drop the evaporator drop in the inner tub position the hanging track and drop in the inner well Never clean the outside housing with a wat...

Страница 12: ...TENTION THE LAMELLAS OF THE CONDENSER COIL ARE VERY THIN AND SHARP AVOID DIRECT CONTACT TO PREVENT INJURIES Please ensure that the air in and air out openings grille for ventilation are NEVER blocked...

Страница 13: ...not begin Customer service The ventilators are not running Customer service The air circulation in the well is blocked Clear the ventilation openings Status display and error notification Message Cau...

Страница 14: ...they are to be removed and replaced immediately by a specialized service representative 12 Maintenance In order to guarantee efficient operation of the refrigerated well along with optimum presentati...

Страница 15: ...m April 2012 Technical changes reserved Page 15 DOC OM_VIAP Vienna Air Pans 12A 13 Wiring diagram Wiring diagram Vienna Air Pans series self contained Wiring diagram Vienna Air Pans series remote refr...

Страница 16: ...P a r t s S e r v i c ed i r e c t 1 8 6 6 7 2 7 0 7 2 1 S e r v i c eE ma i l s e r v i c e r p i i n d u s t r i e s c o m P a r t s E ma i l p a r t s r p i i n d u s t r i e s c o m...

Отзывы: