Valid from: April 2012
Technical changes reserved
Page 12
DOC: OM_VIAP Vienna Air Pans (12A)
Condenser cleaning instructions
Remove air grill / louver in front the condenser.
Remove the dust from the condenser coil; this can be done
with either a brush or a vacuum.
Be careful and don’t bend the lamellas
Replace the air grill panel.
ATTENTION:
THE LAMELLAS OF THE CONDENSER COIL ARE VERY THIN AND SHARP!
AVOID DIRECT CONTACT TO PREVENT INJURIES!
Please ensure that the air-in and air-out openings (grille) for ventilation are NEVER blocked!
CAUTION:
AFTER ALL CLEANING HAS BEEN COMPLETED THE DISPLAY CASE HAS TO
BE RETURNED TO ITS ORIGINAL STATE IN ORDER TO GUARANTEE
EFFICIENT OPERATION!
In addition to daily cleaning, service and maintenance of the cooling cabinet is required to be
carried out in regular intervals by qualified specialists.
(see Chapter 12 MAINTENANCE )