28
User
Manual
Settings
DMX Fail
Hold
Hold= last command retains
Blackout
Blackout= Activates Blackout
Emergency Light
Emergency Light= Fixtures changes to 5600K
AC Fail
Hold
Hold= last command retains
Blackout
Blackout= Activates Blackout
Emergency Light
Emergency Light= Fixtures changes to 5600K
Dimmer Curve
Linear
Linear= Light intensity increases linear
with DMX value
Exponential
Exponential= Light intensity can be set more
smooth at lower DMX values and broadly at
higher DMX values.
Logarithmic
Light intensity can be broadly adjusted at lower
DMX values and more smooth
at higher DMX values
S-Curve
Light intensity can be adjusted smoothly at
lower and higher DMX values and broadly at
medium DMX values
Settings
Dimmer Response
LED
The LED responds abruptly to it´s DMX values
Halogen
The LED responds similar to a halogen fixture
with soft changes at brightness.
Color Calibration
Full Calibration
Color & CCT Calibration
CCT Calibration
CCT only (RAW Colors)
RAW Balance
(affects RAW Mode
in DMX and Stand
Alone Modes
RAW
(R,G,B,L with maximum value of brightnes)
User Calibration
Red (C) <0-
255
>
Green (C)<0-
255
>
Blue (C) <0-
255
>
Lime (C) <0-
255
>
Red (H) <0-
255
>
Green (H)<0-
255
>
Blue (H) <0-
255
>
LED Frequency
800 Hz
Select preferred LED PWM frequency
1200 Hz
2000 Hz
3600 Hz
12000 Hz
25000 Hz
Factory / User Reset
Factory Reset
Are you sure to reset?
Confirm by pressing EN
-
TER, cancel with ESC
Restores all factory defaults including User
Colors, but no User defaults
.
User Reset
Are you sure to reset?
Confirm by pressing
ENTER,
cancel with ESC
Restores all User Reset according to the User
Preset List. Timer Function and DMX adress
restore to Factory default. Once User Reset is
activated a fixture self test will start.