![Roxell Optimax Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/roxell/optimax/optimax_use-and-assembly-manual_1493852017.webp)
ROXELL - 004 - 0715
OPTIMAX - INSTRUCTIONS FOR THE USER
I- 9
TROUBLE SHOOTING GUIDE
Switch off the main switch first.
Use personal protective equipment.
DANGER
ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
PROBLEM
CAUSE
CORRECTIVE ACTION
1.None of the feeder
lines run.
No current.
Replace defective fuses or reset circuit breakers.
Check current supply to the house.
Defective time clock.
Replace defective clock.
Time clock not properly set.
Readjust tabs.
2.One/more lines do
not run.
Pans are empty
Wires from motor damaged.
Measure current in motor wires. Replace wires if
defective.
Motor protection switched off.
See points 3. & 4. Reset motor overload button.
Defective sensor in the control unit, or
sensor not properly adjusted.
Check the good operation of the sensor.
Replace if necessary.
Control unit not functioning properly. Adjust level of control pan. Hang an extra lamp
above it. Check temperature. Control unit must be
the most attractive one, especially the control unit
of the feeder line below the Flex-Auger control unit.
Defective sensor/minimum switch
control unit or 100kg hopper.
Check control unit sensor or switch. Replace if
necessary.
3.Motor is often
overloaded.
Oil on auger overloads the motor.
Clean the auger by running repeatedly 25kgs of
feed through the line.
Not enough current supply to the
motors.
Check current supply at motor location. Start the
motor. Measure start current on motors. Wiring
must be thick enough to guarantee good operation
of the system.
Object blocks the auger. Motor runs,
then stalls. Feed sticks to the tubes.
Check if there are no objects in the boot, the control
unit and the drop holes of the feeder pans. Remove
any objects.
4.Auger stalls.
Anchor bearing worn out or broken.
Replace bearing.
Gently
slide auger back into
the tubes. Don't let it jump back : your
finger
or
the
bearing
could be
damaged
.
Auger not enough stretched.
Shorten the auger.
Object blocks the auger.
Remove the object.
5.Tubes / boot wear
rapidly,
much noise when
system runs.
Auger kinked or bent at the wear
point.
Auger end overlaps the anchor end.
Make sure not to kink the auger when using
gripping pliers. Auger must not overlap the anchor
end.
6.Not enough feed
supplied to fill up
the lines.
Flex-Auger drop holes are too small
or point upwards.
Make
holes
wider/turn
tubes
with
holes
downwards.
Flow regulator in boot of feed supply
system blocks passage of the feed.
Adjust flow regulator to get a higher capacity.
Flex-Auger capacity is too low.
Check the capacity of the Flex-Auger according the
specifications.
Check the installation of the Flex-Auger.
Not enough time set on the time clock. Extend operation time per meal.
7.Feed drops
directly on
the adjuster ring
of the grill.
Pan not installed over the hole.
Remove the top support. Install the pan ass'y over
the hole and the lips.
Содержание Optimax
Страница 8: ......
Страница 9: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Страница 10: ...OPTIMAX INSTRUCTIONS FOR THE USER ROXELL 004 2111 I 2 ...
Страница 24: ...ROXELL 004 2414 OPTIMAX COMPONENTS II 2 GENERAL LAY OUT ...
Страница 40: ...ROXELL 004 4114 OPTIMAX COMPONENTS II 18 11 12 13 14 15 16 17 12 48 CONTROL UNIT WITHOUT PAN 00400911 48 51 ...
Страница 44: ...ROXELL 004 4114 OPTIMAX COMPONENTS II 22 OPTION INTERMEDIATE CONTROL UNIT WITHOUT PAN 00400937 29 ...
Страница 46: ...ROXELL 004 4114 OPTIMAX COMPONENTS II 24 OPTION CONTROL UNIT WITH SENSOR WITHOUT PAN 00400929 45 46 ...
Страница 48: ...ROXELL 004 4114 OPTIMAX COMPONENTS II 26 OPTION INTERMEDIATE CONTROL UNIT WITH SENSOR WITHOUT PAN 00400945 ...
Страница 53: ...III 1 PART III INSTALLATION INSTRUCTIONS ...
Страница 54: ...OPTIMAX INSTALLATION INSTRUCTIONS ROXELL 004 3503 III 2 NOTES ...
Страница 56: ...OPTIMAX INSTALLATION INSTRUCTIONS ROXELL 004 2414 III 2 GENERAL LAY OUT ...
Страница 91: ......