Operation
Instruction manual Folding system
Page 52 of 100
1. Log in as administrator and go to the "Parameter" menu.
2. Correct the deviations under "Fan folding" and "Cross folding".
e.g.: If you measure an overlap of 0.08” in the document back
edge during fan folding, correct the document back edge
by -0.08”.
3. Confirm your changes with "Apply".
Fan folding package folding:
Machine folding – with a remaining length < 90mm the last layer
will be folded left-justified
DIN folding – with a remaining length < 90mm the last layer will be
folded according to DIN 824.
Cross folding mode:
Mode 1 = With a remaining length < 90mm the last layer will be
folded halfway.
Mode 2 = with a remaining length < 90mm the last layer will not
be folded anymore.