~ 13 ~
possible setting to maximize TCP/IP performance. Maximum value =
1420 (at 9600) bytes.
NOTE: This value is set automatically when the baudrate is set, in an
attempt to optimize the link. It is assumed that higher baudrates equates
to more data and hence the flush size is increased.
Flush size is one of three ways to control TCP/IP packet forwarding. The
others are match character and timer. For more information see section
10.4 on UART Receiver.
set comm time <num>
sets the flush timer. An IP packet will be sent if no additional bytes are
received for “num” milliseconds. Num is one milliseconds interval. 1 is
the minimum value. Default is 10 (10 milliseconds). Setting this value to 0
will disable forwarding based on the flush timer.
Flush timer is one of three ways to control TCP/IP packet forwarding.
The others are match character and size. For more information see section
10.1 on System Timers and Auto Connect Timers
5.4.
DNS Parameters
set dns address <addr>
sets the IP address of the DNS sever. This is auto-set when using DHCP,
and needs to be set in STATIC IP or Auto-IP modes.
set dns name <string>
sets the name of the host for TCP/IP connections.
set dns backup <string>
sets the name of the backup host for TCP/IP connections.
5.5.
FTP Parameters
set ftp filename <file>
sets the name of the file transferred when issuing the “ftp u” or “ftp g”
commands.
set ftp addr <addr>
sets the ftp server IP address.
set ftp remote <port>
sets the ftp server remote port number (default is 21).
set ftp user <name>
sets the ftp user name for accessing the FTP server.
set ftp pass <pass>
sets the ftp password for accessing the FTP server.