background image

Important Safeguards – Outdoor Use

 

GRAPHIC SYMBOL EXPLANATION 

The lightening bolt symbol alerts the user to the presence of 

dangerous voltage that may present the risk of electric shock. 

 

The exclamation point symbol alerts the user to the presence of 

important operating and maintenance instructions. 

 

1. Read Instructions -

 Read all safety and operating instructions 

before the product is operated. 

2. Retain Instructions -

 Retain all safety and operating 

instructions for future reference. 

3. Heed Warnings -

 Pay attention to all product warnings. 

4. Follow Instructions -

 Follow all operating instructions. 

5. Cleaning -(Do not use caustic, abrasive or aerosol 

cleaners) 

 

a)  For units that CAN BE DISCONNECTED from the power 

source, use a damp cloth for cleaning. 

b) For

 

units that CANNOT BE DISCONNECTED from the 

power source, use a damp cloth for cleaning and do not 
allow moisture or liquids to enter vents. 

6. Attachments -

 Use only UL Listed Vicon recommended 

attachments to prevent unit damage and personal injury. 

7. Water and Moisture -

 Use only products designed for outdoor 

environments where they will be exposed to water or moisture. 

8. Accessories -

 Do not place the unit on an unstable surface to 

avoid falling. Use only UL Listed Vicon recommended mounting 

accessories. 

9. Ventilation -

 Do not block ventilating slots and openings as 

they ensure reliable operation. Do not place the unit near a heat 

source or into an enclosure unless recommended by Vicon. 

10. Power Sources -

 The product should only be operated from 

the recommended power source. Use only a UL Class 2 

indoor/dry or Class 3 outdoor/wet power supply. 

11. Grounding -

 Only products equipped with a 3-prong 

grounded plug should be inserted into a grounded power outlet. 

Contact an electrician to replace an obsolete outlet. Do not force 

a plug into a non-grounded outlet. 

12. Power Cord Protection -

 Power supply cords should not be 

routed in trafficked areas or in tight spaces where they will be 

pinched or used to bear weight. Allow some slack in the cord 

where it enters the unit. 

13. Outdoor Cable Grounding -

 Use only grounded outdoor 

cables to protect against voltage surges and static charges. 

Section 810 of the National Electrical Code, ANSI/NFPA 70-

1984, provides information on proper grounding of the lead-in 

wire to an antenna discharge unit, size of grounding conductors 

and the requirements of grounding electrodes. 

14. Lightning -

 Disconnect the product from its power source 

and cable system when possible to prevent damage due to 

lightning and power-line surges. 

15. Power Lines -

 Do not locate outside cables over power or 

utility lines where they can fall and make direct contact. Contact 

with power lines can be fatal. 

16. Overloading -

 Do not overload wall outlets and extension 

cords to prevent risk of fire and electric shock. 

17. Object and Liquid Entry -

 Never probe through, or spill 

liquid into, enclosure openings to prevent risk of fire or electric 

shock. 

18. Servicing -

 Refer all servicing to qualified service personnel. 

19. Damage Requiring Service -

 Obtain service when: 

 

a) 

The power-supply cord or plug is damaged. 

b)  Objects have fallen or liquid has been spilled into the 

product. 

c) 

The product is not designed for outdoor use and has been 
exposed to water or moisture. 

d) 

The product does not operate per the operating instructions. 
Perform Vicon recommended adjustments, modifications 
and troubleshooting only to avoid unit damage and personal 
injury. 

e) 

The product has been dropped. 

f) 

The product shows a significant change in performance. 

 

20. Replacement Parts -

 Use only Vicon specified replacement 

parts or an approved equivalent to prevent unit damage and 

injury. 

21. Safety Check -

 Request safety checks to be performed 

following repair or maintenance to verify proper operation. 

22. ESD Precaution -

 Take all normal electrostatic discharge 

precautions to avoid component damage during installation and 

operation. 

23. For 230 VAC Devices Only -

 When the disconnect device is 

not incorporated in the equipment or when the plug on the power 

supply is intended to serve as the disconnect device, follow the 

guidelines below: 

a)  For permanently connected 230 VAC units, a readily 

accessible disconnect device must be incorporated into the 

site wiring. 

b) 

For 230 VAC units with a plug, the outlet must be installed 

near the unit and be easily accessible. 

 

 

Содержание V910A-WDR

Страница 1: ...or this purpose Copyright 2009 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc Roughneck is a trademark of Vicon Industries Inc Dow Corning is a registered trademark of Dow Corning Corporation VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 63...

Страница 2: ......

Страница 3: ...ment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If necessary the user should cons...

Страница 4: ...unding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenna discharge unit size of grounding conductors and the requirements of grounding electrodes 14 Lightning Disconnect the product from its power source and cable system when p...

Страница 5: ...le Connections 6 Video Cable 6 Coaxial 6 Twisted Pair 6 Fiber 7 Camera Power Connections 8 Heater Connections 8 Camera Synchronization 9 Camera Lens Adjustments 9 Switch Settings 9 Lens Autoiris Adjustment 9 Final Installation 10 Operation 11 Maintenance 11 Shipping Instructions 12 Reference 13 Technical Information 15 Vicon Standard Equipment Warranty 18 XX137 60 00 Rev 109 Roughneck V910 Dome Ca...

Страница 6: ... Installation For complete detailed instructions on how to install the V910 read the Installation section Installation Diagram ii 3BQuick Installation XX137 60 00 Rev 109 Roughneck V910 Dome Cameras with WDR ...

Страница 7: ... with a 3 3 12 mm lenses the camera includes an isolated power input The camera accepts 24 VAC The varifocal lens allows for lens adjustment capability and autoiris adjustment is available by a potentiometer The Wide Dynamic Range feature provides the best possible image in any light conditions The basic V910 provides video transmission over coaxial cable Options are available that provide fiber o...

Страница 8: ...The Roughneck V910 units consist of a base which includes the camera mounting bracket with the camera lens assembly and a cover with a smoked dome Refer to Figure 1 Base Camera Mounting Bracket The base of the unit is constructed of die cast aluminum The base is mounted directly to the wall or ceiling Two cable access holes are provided A safety cord is provided to connect the cover to the base Th...

Страница 9: ...Figure 1 Exploded View XX137 60 00 Rev 109 Roughneck V910 Dome Cameras with WDR 5BInstallation 3 ...

Страница 10: ...an support the weight of the unit the V910 unit weighs 4 lb 1 8 kg Video and power cables must be routed to the installation location The V910 mounts directly to a ceiling or wall The base has four mounting holes and two cable access holes are provided As a mounting alternative the mounting holes align with a standard 4 x 4 electrical box and the unit may be mounted to that Refer to Figure 2 To mo...

Страница 11: ... side cable access hole is used the base must be mounted so the hole is pointed directly downward Figure 3 Installation Options 5 Fasten the base to the wall or ceiling with the appropriate hardware for the mounting surface lag bolts and sleeve for cement surfaces or machine screws for other surfaces A nylon washer is provided at each mounting hole for environmental sealing If the rear cable acces...

Страница 12: ...l and UTP versions and 5B fiber version when performing these connections Refer to the Coaxial or Twisted Pair Cable Recommendations in the Reference section Video Cable Coaxial To connect video cables to the camera attach a customer supplied male BNC connector to the mating BNC connector on the pendant cable on the camera power supply board Refer to Figure 1 Note After mating the male female BNC ...

Страница 13: ...ht into the unit via the fiber cable connected to a standard ST connector on the board U4 A video focus adjustment connector is provided on the camera board for use with a portable local monitor for making adjustment On the fiber version a second connector is provided on the PC board J4 for use with a portable local monitor for making video adjustment A video adjustment cable is supplied in the ac...

Страница 14: ...imately 0 25 in 6 mm of insulation off each individual wire Refer to Figure 6 Connect the wire into the terminal block Repeat for each connection Refer to Table 2 3 Connect the terminal block onto the board connector The camera is shipped prepared for 24 VAC Figure 6 Cable Preparation Table 2 Camera Power Connections Pin Number Function 1 24 VAC 2 24 VAC Return Note A grounding tab is provided on ...

Страница 15: ...s 7 and 8 for the location and setting of the switches To obtain the sharpest picture possible the iris adjustment should be made from a full bright setting down to an acceptable video level This assures that the internal AGC of the camera is not operational See Table 3 for camera and lens specifications Lens Autoiris Adjustment The lens can be manually adjusted for focus and zoom On the lens focu...

Страница 16: ...Final Installation After all cable connections are made test the camera lens to see if any further adjustments are necessary Align the viewing slot in the mask with the camera lens assembly Reattach the cover to the base by aligning the four captive screws with the holes in the base Any alignment of holes and screws is acceptable The cover can be rotated 90 by aligning the screws holes differently...

Страница 17: ...ir cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of 50 isopropyl alcohol and 50 water using a microwave safe aluminum free paper towel Dry with clean dry pressurized air 4 Scratches or surface blemishes on the exterior or interior may be removed with a nonabrasive wax using a soft cleaning cloth Either liquid or spray cleaner wax suitable ...

Страница 18: ...ed Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstances under which it occurs f Unit s original date of purchase if still ...

Страница 19: ...ter video quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a guide in choosing the best cable type For cables other than the approved Vicon types below contact the manufacturers listed below Note that BC refers to bare copper and TC refers to tinned copper Recommended Coaxial Cable Types Cable Type Belden Type No Alpha Type ...

Страница 20: ...nt as a twisted pair the blue white white blue wires twisted together as a pair not a split pair blue white conductor part of one pair orange white conductor part of another pair Choose a Belden or equivalent cable type by referring to the characteristics and maximum distances listed below The characteristics of the cables in the Tables should be used as a guideline when cables other than Belden a...

Страница 21: ...the conversion of 100 of the electrical energy to heat Actual percentage of heat generated will be less and will vary from product to product These figures are provided as an aid in determining the extent of cooling required for an installation Connectors Coaxial and UTP Models Power 2 pin screw terminal Video BNC on pendant cable or UTP terminal Heater 2 pin connector Fiber Model Power 2 pin scre...

Страница 22: ...m Dome Diameter 4 7 in 119 mm Weight Approximately 4 lb 1 8 kg Construction Base Cover die cast aluminum Dome injection molded polycarbonate plastic Finish Base Cover painted light beige Dome smoked ENVIRONMENTAL Housing Evaluated to UL standard 50 with an environmental rating of 4X Operating Temperature Range 22 to 140 F 30 to 60 C Operating Humidity Up to 95 relative noncondensing Storage Temper...

Страница 23: ...1 interlace NTSC PAL Color 480 0 06 0 6 at 30 IRE f 1 2 AGC on Line Lock WDR ON OFF White Balance ATW AWB Iris Setting ME AE AGC ON OFF NTSC 1 60 1 100 000 PAL 1 60 1 100 000 45 dB AGC off Lens Specifications Focal Length Field of View mm Horizontal Vertical 3 3 12 varifocal with autoiris 83 9 23 91 61 9 17 93 XX137 60 00 Rev 109 Roughneck V910 Dome Cameras with WDR 10BTechnical Information 17 ...

Страница 24: ...ompany are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no cost may be discontinued at any time without notice at Vicon s sole disc...

Страница 25: ...XX137 60 00 Rev 109 Roughneck V910 Dome Cameras with WDR 11BVicon Standard Equipment Warranty 19 Notes ...

Страница 26: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 47 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Отзывы: