background image

2200293 

_5982

2016 05 02

English

EN

Disconnecting tools

 Important! 

Special requirements may 

apply to individual tools. Read the tool 

documentation in this regard.

 DANGER! 

No one may be present 

within the machine’s working area when 

tools are connected, replaced or set 

down. Tools may come lose or overturn 

unexpectedly during the connection 

procedure, causing injury or damage.

Procedure for disconnecting tools

•  Check that nobody is present within the 

machine’s working area.

•  Lift the tool.
•  Operate the tiltrotator so that the tool hangs by 

its front shaft and press the rear shaft towards 

the tool (see figure 17).

 Important! 

It is extremely important 

that the tool be tilted inward, otherwise 

the tool may fall unexpectedly when 

the coupler is opened.

•  Open the quick coupler as per the Control 

system section.

•  Make sure the indicator rod is visible  

(see figure 18).

•  Operate the tiltrotator so that the tool is only 

hanging by its forward shaft (see figure 19).

•  Lower the tool to the ground. The ground must 

be firm and even.

•  Retract the bucket cylinder until the angle to 

the quick coupler and the attachment is 30°-45° 

(see figure 20).

•  Free the front shaft from the attachment and 

raise the boom.

•  Lock the quick coupler according to the Control 

system operation section.

•  Check that the quick coupler is locked and that 

the cover protecting the quick connect fittings is 

closed.

Figure 17

Figure 18

Figure 19

Figure 20

approx 30 cm

30°-45°

Содержание Quick Change QC45

Страница 1: ...ction of the cylinder unit has space for hydraulic quick connect fittings When the unit s cylinders move the quick coupler locks and the hydraulics are connected simultaneously Connection and disconne...

Страница 2: ...1 1 2 3 4 3 4 3 8 3 8 QC60 5 E2 HF E2 HF L 3 4 5 2 1 3 4 1 2 1 2 QC65 L E2 HF E2 HF 3 4 3 4 English EN Quick connect fittings QuickChange quick connect fittings are fitted in the center section of the...

Страница 3: ...rea Open the quick coupler lock as described in the Control system operation section Make sure the indicator rod is visible figure 8 Rotate the quick coupler so that the part furthest away becomes vis...

Страница 4: ...o the tool s front shaft Lift the tool from the ground so that it hangs freely figure 12 Operate the tiltrotator such that the quick coupler s rear part moves down toward the tool s rear shaft figure...

Страница 5: ...Figure 15 Figure 16 Correctly connected Incorrectly connected IMPORTANT Checking the quick coupler lock Even if the indicator shows the locking wedge to be in the locked position conduct the followin...

Страница 6: ...Important It is extremely important that the tool be tilted inward otherwise the tool may fall unexpectedly when the coupler is opened Open the quick coupler as per the Control system section Make sur...

Страница 7: ...ule see figure 21 In certain cases it may be necessary to adjust the tool Refer also to the grapple module s instructions for use Extra grapple function The extra function enables the use of a grapple...

Страница 8: ...otective cover is working as intended Check that there are no leaks The quick coupler and the tool attachment must be kept free of snow and ice in winter As necessary hose or wipe away sand ice and sn...

Страница 9: ...grease points Quick coupler grease points are shown below The table lists a description of grease points their number and greasing frequency Pos Description Number of lubrication points Interval 1 Gui...

Страница 10: ...use the nose seal is probably damaged and must be replaced Replacing the nose seal quick connect fitting 1 Remove the damaged nose seal 2 Carefully clean around the seat of the fitting 3 Install the...

Страница 11: ...e support ring must be inserted first black marking facing up toward the pusher followed by the O ring Then place the pusher on a table or other flat surface and press the seal to the bottom with the...

Страница 12: ...he quick connect fitting is now accessible Remove and scrap the locking ring and the steel washer 6 behind it On 1 quick connect fittings fastened with screws remove the screws and their washers and s...

Страница 13: ...Pressure relief valve defective Oil leak from the quick connect fittings when the tool is connected The nose seal is missing or damaged Replace the nose seal as described in the section Replacing the...

Страница 14: ...H Max 125 Max 150 Max 150 Max 150 Max 250 Max250 Max 250 I 291 5 0 5 341 5 0 5 341 5 0 5 441 1 0 451 5 0 5 551 1 0 591 5 0 5 J 45 f8 60 f8 60 f8 65 f8 70 f8 70 f8 80 f8 K Max 520 Max 600 Max 600 Max...

Страница 15: ...2200293 _5982 2016 05 02 English EN Hydraulics diagram quick coupler locking function...

Отзывы: