background image

5

A

B

A 5 mm Allen (Hex.) key and 0.8 x 4 mm flat screwdriver are 
required to perform commissioning of the CK Mechanical 
Switch Mechanism.

Set torque limits

Indicator/Adjustment Point

Torque Cam Clutch Screw

1)  Move the valve to a mid-travel position and loosen the 

Torque Cam Clutch 1.5 turns using a flat screwdriver.

2)  Adjust each Torque Cam to the desired value (between 

min. & max.) by moving the cam using a screwdriver on the 
adjustment point.

 CAUTION: Ensure the screwdriver remains 

perpendicular to the switch mechanism faceplate 
when adjusting the torque trip limits to avoid 
introducing an offset to the set value.

3. Commissioning

C

  Open Torque Adjustment Point

D

  Close Torque Adjustment Point

3)   Tighten the Torque Cam Clutch Screw once both torque 

trip limits have been set.

 CAUTION: Ensure the Torque Cam Clutch Screw is 

tightened enough to fully deform the spring washer 
underneath the screw head.

E

  Factory Calibration Fixings

 WARNING: Do not adjust the fixings or position 

of the yellow torque indicator plates. These are 
factory configured for 40-100% adjustment of the 
actuator torque and under no circumstances should 
be moved.

C

D

E

A4

US

US

A4

US

A4

US

A4

A4

US

 US

 A4

 US

 A4

A4

US

Содержание CK Atronik Series

Страница 1: ...CK Range CKa CKra Atronik Start Up Guide Modular Design Electric Valve Actuators...

Страница 2: ...ver 1 000 service technicians are employed by our company partners and representatives providing the necessary worldwide infrastructure to fully support actuators in the field 1 CK Valve Actuation Wor...

Страница 3: ...ar 11 Serial No Code Bar 12 QR Code 13 IP Degree 14 Address Atronik Name Plate Conduit Entries Switch Mechanism Cover Protective Earth Connection M6x1p x 10 Deep Plug and socket housing Atronik Interf...

Страница 4: ...move the actuator to a mid travel position and confirm that none of the switches are active before beginning the test procedure 2 Test position switches in both directions using a flat screw driver to...

Страница 5: ...river remains perpendicular to the switch mechanism faceplate when adjusting the torque trip limits to avoid introducing an offset to the set value 3 Commissioning C Open Torque Adjustment Point D Clo...

Страница 6: ...ct direction This is done to avoid the need to wind through the whole mechanism to reach the limit position The correct direction to approach the limit is shown by the arrow next to the Adjustment Scr...

Страница 7: ...rform two checks to confirm the OPEN limit position switch has been made correctly a The feel of the Adjustment Screw will noticeably change providing more mechanical resistance at the switching point...

Страница 8: ...k on the Atronik status indicators during switch testing The main power supply must be maintained during this test procedure to ensure feedback via the Atronik It is not possible to test a switch that...

Страница 9: ...orientation can be adjusted through 360 in 90 increments If this is a requirement then the following instructions must be adjusted by the same increment in the same direction 1 Move the actuator to th...

Страница 10: ...Screw by 1 turn whilst holding the CLOSE portion of the Position Disc 8 Rotate only the red OPEN portion of the disc so that OPEN reads horizontally and then hold both portions in place 9 Tighten the...

Страница 11: ...long the shaft against the spring to allow free rotation of the cam 3 Rotate the cam to ensure the desired switch behaviour is achieved The intermediate position switches can be supplied with normally...

Страница 12: ...ntil the POT cannot rotate any further Confirm the POT is triggering the Close Limit indicator on the Atronik or reading the required resistance value 6 Refit the POT assembly to the AID chassis and e...

Страница 13: ...the actuator to the Closed position limit using electrical operation or the handwheel 2 Connect a powered test meter across the CPT terminals and measure the transmitted current refer to actuator wir...

Страница 14: ...B ON No Priority PRIORITY B OPEN ACTION Open Action Stop on position limit Stop on torque limit CLOSE ACTION Close Action Stop on position limit Stop on torque limit LED LED Green Close Red Open Red C...

Страница 15: ...edback is transmitted via 4 20 mA to provide remote intermediate position indication Switch No Function OFF ON SW5 6 Positioner Inverse Control signal is Close low Open high Control signal is Close hi...

Страница 16: ...isit our website at www rotork com The name Rotork is a registered trademark Rotork recognizes all registered trademarks Published and produced in the UK by Rotork POWJB0320 Rotork plc Brassmill Lane...

Отзывы: