![Rotex RKHB 016BA3V3 Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/rotex/rkhb-016ba3v3-series/rkhb-016ba3v3-series_operation-manual_1491131033.webp)
RKHBH/X016BA
Indoor unit for air to water heat pump system and options
4PW54227-1
Operation manual
15
9
Heating and cooling set point ranges
00
Heating set point upper limit
55
37~55
1
°C
01
Heating set point lower limit
25
15~37
1
°C
02
Cooling set point upper limit
22
18~22
1
°C
03
Cooling set point lower limit
5
5~18
1
°C
04
Installation related setting
A
Quiet mode
00
Quiet mode type
0
0/2
—
—
01
Parameter 01
3
—
—
—
02
Not applicable
1
Read only
—
—
03
Not applicable
0
Read only
—
—
04
Not applicable
0
Read only
—
—
b
Not applicable
00
Not applicable
0
Read only
—
—
01
Not applicable
0
Read only
—
—
02
Not applicable
0
Read only
—
—
03
Not applicable
0
Read only
—
—
04
Not applicable
0
Read only
—
—
D
Local shift value weather dependent
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Local shift value weather dependent
0
0/1/2/3/4
—
—
E
Unit information readout
00
Software version
Read
only
—
—
—
01
EEPROM version
Read
only
—
—
—
02
Unit model identification
Read
only
—
—
—
03
Liquid refrigerant temperature
Read
only
—
—
°C
04
Inlet water temperature
Read
only
—
—
°C
F
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range
Step
Unit
Date
Value
Date
Value