A
B
C
D
G
F
E
25. Electrical For E Series Lifts:
Have a certified electrician run power supply to slave side
disconnect, Fig. 31a for three phase. Size wire for 25 amp circuit.
See Motor Operating Data Table.
IMPORTANT
Use separate circuit for each power supply.
Protect each circuit with time delay fuse or circuit breaker. For
single phase 230V, use 20 amp fuse. For three phase 400V, use
10 amp fuse. All wiring must comply to all local electrical codes.
Wire motor according to wiring diagram provided on page 22.
IMPORTANT
As with all electronic equipment, the inbay con-
trol modules can be affected by voltage irregularities. It is the lift
owner's responsibility to ensure that adequately protected power
sources are available for connecting this equipment.
NOTES:
1. Unit not suitable for use in unusual conditions. Contact
Rotary Lift for moisture and dust environment duty unit.
2. Motor rotation is counter clockwise from top of motor.
MOTOR OPERATING DATA - THREE PHASE
400 - 415 Volts 50Hz
LINE VOLTAGE
CURRENT
POWER
4.55A - 3Kw
MOTOR OPERATING DATA - SINGLE PHASE
220 - 240 Volts 50Hz
LINE VOLTAGE
CURRENT
POWER
17A - 1.5Kw
Fig. 32
Fig. 32 Single Phase Motor Wiring
220V/50Hz
A Connection from Master Control panel.
B N
C L1
D Black Wire
E White Wire
F Capacitor
G Ground Connection
Hochspannung
440V, 50Hz
L3
L2
L1
T3
T2
T1
T9
T8
T7
T6
T5
T4
21
Содержание SPO54E
Страница 2: ...Fig 1 Fig 2 A B C D E F G H I J A B C D E F G H I J 2...
Страница 31: ...NOTES...