A
C
B
Installing Electrical And Inbay Controller Components
For E Series Lifts.
20. Solenoid Attachment:
Attach solenoids under locking latches
of both columns, Fig. 26. Place sliders onto solenoid plunger
rods. Place solenoids onto columns and tighten, Fig. 26.
Fig. 26
21. Installing Master Control Panel & Tool Holder:
Remove access panel from the master control panel (master
control panel has 5 cables attached to it), Fig. 27.
Install (2) 5/16"-18NC x 3/8" PHMS screws in holes on each side
of the locking latch (power unit side) leaving approximately 3mm
exposed to hold the panel. Hang the master control panel
over locking latch to column on the 5/16"-18NC x 3/8" PHMS
screws and pull the locking latch solenoid wire through the panel,
Fig. 27. Plug locking latch solenoid into master control panel.
Connect the ground wire ring terminal to one of the lock solenoid
mounting screws, Fig. 26.
Install (1) 516"-18NC x 3/8" PHMS in bottom of master control
panel. Tighten down all (3) screws. Do not install access panel
back into control panel at this time. It will be reinstalled in a later
step.
21a.
Install one of the air tool holders under the master control
panel with two 5/16"-18NC x 3/8" PHMS, Fig. 27.
Fig. 26 Detail
A
WICHTIG
Attach slider to solenoid plunger
rod.
B 5/16"-18NCx3/8" PHMS Place screws through sole-
noid and attach to column.
C
Solenoid ground wire from control panel.
15
Содержание SPO54E
Страница 2: ...Fig 1 Fig 2 A B C D E F G H I J A B C D E F G H I J 2...
Страница 31: ...NOTES...