22. Routing Motor and Master Cables:
From the master control panel route cables up through
column along the hose routing, Fig. 28.
Fig. 28
Fig. 29 Detail
A 5/16"-18NCx3/8" PHMS, Leave these two screws
exposed out of the column approximately 3mm.
B
IMPORTANT
Slave control panel always mounts
on opposite column of the power unit.
C
Access Panel
D 5/16"-18NCx3/8" PHMS, Through the control panel.
E
Tool Holder
F
5/16"-18NCx3/8" PHMS
G Pull connector through panel
Fig. 28 Detail
A Master control wire routing
follows hydraulic hose routing
A) Locate the overhead switch cable at the master cable
connector. Feed the overhead switch cable through the
strain relief and into the overhead switch box, Fig. 30.
B) Attach lowering valve cable to lowering valve and tighten
screw on top, Fig. 30.
C) Run the motor cable though strain relief in the motor
junction box. Motor wiring and wire diagrams are detailed
in, Fig. 32.
23. Installing Slave Control Panel & Tool Holder:
Remove access panel from the slave control panel, Fig. 29. Place
(2) 5/16"-18NC x 3/8" PHMS screws in holes on each side of the
locking latch leaving approximately 3mm exposed to hold the
panel. Hang the slave control panel over locking latch to column
on the 5/16"-18NC x 3/8" PHMS screws and pull the locking latch
solenoid wire through the panel, Fig. 29. Connect the ground wire
ring terminal to one of the lock solenoid screws, Fig. 26. Install (1)
5/16"-18NC x 3/8" PHMS in bottom of slave control panel. Do not
install access panel back into control panel at this time. It will be
reinstalled in a later step.
23a.
Install one of the air tool holders under the slave control
panel with two 5/16"-18NC x 3/8" PHMS, Fig. 29.
Fig. 29
17