background image

5

Lights on/off 

(Optional Accessory) 

Activate Column Buttons 

(8 Total) 

Lower To Locks 

Height Limit Setting 

Battery Charge Indicator 

System Configuration 

Lock/Unlock 

Single/Pair/All Mode 

E-Stop 

Raise 

Lower 

Slow Lower 

Yellow, Green, Red

Activation LED’s

(8 Total)

Data Information 

Display and Buttons 

Quick Start Operating Instructions

Control Panel Diagram 

1.  The service area must be clear of all personnel before 

the vehicle is positioned.

WARNING  

Locate lift on level concrete surface with a 

minimum strength of 3000 psi.

2.  Spotting: Position the vehicle in the location where it is 

to be lifted.

Note: See Fig. 2 for the general arrangement of each lift 

column.

3. Loading:

Position one column at a lifting wheel location.  Position 

so that the forks are under the tire and the unit is pushed 

in as far as possible, Fig. 3.  Ensure fork width is adjusted 

to properly accommodate the tire/wheel size.  Turn on the 

Power Up Switch, Fig. 4.

4.  Using the Control Panel and the bus diagram as a 

reference (see graphic above), press the Activate Column 

Button relative to the location where the column was just 

placed.  The column will show Green when activated.

5.  Plug the fixed length communication cable from the cord 

reel into the bottom of the control panel.

6.  Position next column at second wheel using loading 

instructions from step 3.

7.  Run the reel-end of the communication cable from the 

first column and plug into the side of the control panel on 

the second column.   Turn on second column.  Again, using 

the Control Panel and the bus diagram as a reference, press 

the Activate Lift Button relative to the location of the second 

column.  The lift will show Green when activated.  The first 

lift you activated should now be flashing yellow on your 

control panel.

8.  Repeat step 5 thru 7 for remaining columns.  When 

the entire system of columns is complete, press the 

System Configuration Lock/Unlock button to lock the lift 

configuration for operation.

NOTE:  The electrical communication cables do not 

have to make a complete loop.  You do not have to plug 

the last lift back into the first lift. 

Содержание MCH418

Страница 1: ...418 MCH618 Four Post Six Post Mobile Column Lift 24V DC Powered June 2015 by Vehicle Service Group All rights reserved CO9304 4 IN20540 Rev G 6 12 2015 MCH418 Capacity 72 000 lbs MCH618 Capacity 108 0...

Страница 2: ...rent batteries meeting the below specifications may be used but performance can vary Recommended Battery Specifications 12V DC Sealed Deep Cycle Battery Size 31 Frame Group 105 AH Capacity At 20 AH Ra...

Страница 3: ...approval from structural engineer Upon completion of the assembly of the lift the lift is to be operated to assure proper function Observe for locks operating in all locking positions each side lifts...

Страница 4: ...e manufacturer s operating instructions ALI SM 93 1 ALI Lifting it Right safety manual ALI ST 90 ALI Safety Tips card ANSI ALI ALOIM 2000 American National Standard for Automotive Lifts Safety Require...

Страница 5: ...Control Panel and the bus diagram as a reference see graphic above press the Activate Column Button relative to the location where the column was just placed The column will show Green when activated...

Страница 6: ...S DO NOT RUN CABLES IN EXIT PATH OF AUTOMOBILE Communication Cable DO NOT RUN CABLES IN EXIT PATH OF AUTOMOBILE Communication Cable Fig 3 Fig 4 Fig 2 NOTE Ensure Communication Cables are clear of fork...

Страница 7: ...that the System Configuration Lock Unlock light is green press the Raise Button to raise lifts off the locks B Press the Lower Button to lower lift The Slow Lower Button 1 3 speed can be used if desi...

Страница 8: ...column with an error Operating Instruction Details Options Changing the System Configuration Columns may only be added to or removed from a system by unlocking the existing configuration and then con...

Страница 9: ...ORKING IN THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES CONTAIN SULFURIC ACID AND PRODUCE EXPLOSIVE GASES A BATTERY EXPLOSION COULD RESULT IN LOSS OF EYESIGHT OR SERIOUS BURNS FOR THIS RE...

Страница 10: ...1 Lower lift check oil level in oil tanks on each column Open Power Unit Cover Remove oil cap and check oil level It should just be touching the dipstick If necessary fill with ISOVG32 hydraulic oil...

Страница 11: ...nger be guaranteed Follow manual lowering procedures E7 Short circuit detected A short has been detected in the lift actuators Press x to clear To determine the faulty component run the faulty column...

Страница 12: ...nect switch is OFF if one is provided on the lift 3 The authorized lockout person operates the main energy isolation device removing power to the subject lift If this is a lockable device the authoriz...

Страница 13: ...nal See Supplemental Diagram String NP932 Rev A AC in 230 V 2 2A 1 50Hz Battery Charger RS485 Comm Pot Contactors Red Black Black Red White Blue Black 1 White Black 2 Red Red Black Red Black Black Red...

Страница 14: ...14 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 15: ...15 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 16: ...e to lift owner operator Thank You Trained Operators and Regular Maintenance Ensures Satisfactory Performance of Your Rotary Lift Contact Your Nearest Authorized Rotary Parts Distributor for Genuine R...