Index

Set-Up Instructions  .................................................. 2

Safety Instructions  ................................................... 4

Owner/Employer Responsibilities  .......................... 4

Quick Start Operating Instructions  ........................ 5

Emergency Lowering ................................................ 7

Detailed Operating Instructions .............................. 8

Battery Charging ........................................................ 9

Maintenance Instructions  ..................................... 10

Trouble Shooting ...................................................... 11

Lift Lockout/Tagout Procedure .............................. 12

Wiring Diagram ........................................................ 13

Set-Up Instructions

Follow these instructions to ensure a satisfactory set-up 

and operation of the lift.

•  After set-up and inspection of the lift, please return this 

booklet  to the literature package and give to lift owner/

operator.  Literature package should be kept attached to 

controls for easy access.

1.  Unloading:  Rotary’s Mobile Lift System units are shipped 

in the vertical position.

2.  After unloading, remove and discard protective 

wrapping. 

NOTE:  Unit is shipped without batteries and 
without power unit fluid.  Installation of both 
batteries and fluid MUST be completed prior 
to lift operation.

  Failure to do so will result in air 

entering the system.  The unit will then have to be 

bled.

3.  To move the column, remove protective banding and 

wheel clamps from wheel jack.  The forklift brackets can be 

removed from the side of the column if desired.

4.  Open power unit cover by removing the 3 M8 BHCS 

(Button Head Cap Screw).  Fill power unit tank with 

ISOVG32 hydraulic oil.  Tank capacity is approximately 11-

1/2 quarts (11 liters).  Fill until fluid is just barely visible on 

dipstick.

5.  Install two batteries in location shown, Fig. 1.  Through 

our research Rotary recommends Exide

®

 brand battery 

part number NG-27 or DEKA

®

 brand battery part 

number DC31DT.  Different batteries meeting the below 

specifications may be used but performance can vary.  

Recommended Battery Specifications:

12V DC Sealed Deep Cycle Battery

Size 31 Frame Group

105 AH Capacity (At 20 AH Rate)

Stud Terminals with Stainless Steel Wing nuts

Battery wires are clearly marked/labeled inside the unit 

itself.

Install tie-down straps on batteries as shown.  

Close lift and re-install M8 BHCS removed earlier.

After the batteries and fluid have been added, screw M20 

bolt and M10 socket head bolts clockwise on wheel jack 

and front of superstructure to adjust unloaded column 

ground clearance, Fig. 1.  Ground clearance is determined 

by how far the bolts are turned.  When the column is 

loaded, it will automatically lower to the floor.

WARNING  

 Permit only trained personnel to 

operate lift.  After reviewing these instructions, 

become familiar with the lift controls by running the lift 

through a few cycles before loading a vehicle on lift. 

Observe and heed SAFETY and WARNING labels on 

the lift.

                                                                           

WARNING  

 This motor has internal arcing or 

sparking parts.  To minimize the Risk of Explosion, DO 

NOT expose to flammable vapors.  

OPERATING CONDITIONS:  Lift is not intended for 

outdoor use or storage and has an operating ambient 

temperature range of 41º-104ºF (5º-40ºC).

DO NOT use lift in a manner other than intended.  

Included (but not limited to) examples of unapproved 

uses of the lift are: lifting vehicle by only one side, 

lifting different axles with a column pair (lifting on the 

diagonal), and lifting non-approved items. 

6.  Bleed mobile columns:

a.)  Raise forks 150-200mm do not lift forks high enough to 

engage locks.

b.)  Loosen bleed screw to release air from system.

c.)  Close screw and repeat steps a and b until there is no 
air in the system and fluid runs clear. 

Содержание MCH418

Страница 1: ...418 MCH618 Four Post Six Post Mobile Column Lift 24V DC Powered June 2015 by Vehicle Service Group All rights reserved CO9304 4 IN20540 Rev G 6 12 2015 MCH418 Capacity 72 000 lbs MCH618 Capacity 108 0...

Страница 2: ...rent batteries meeting the below specifications may be used but performance can vary Recommended Battery Specifications 12V DC Sealed Deep Cycle Battery Size 31 Frame Group 105 AH Capacity At 20 AH Ra...

Страница 3: ...approval from structural engineer Upon completion of the assembly of the lift the lift is to be operated to assure proper function Observe for locks operating in all locking positions each side lifts...

Страница 4: ...e manufacturer s operating instructions ALI SM 93 1 ALI Lifting it Right safety manual ALI ST 90 ALI Safety Tips card ANSI ALI ALOIM 2000 American National Standard for Automotive Lifts Safety Require...

Страница 5: ...Control Panel and the bus diagram as a reference see graphic above press the Activate Column Button relative to the location where the column was just placed The column will show Green when activated...

Страница 6: ...S DO NOT RUN CABLES IN EXIT PATH OF AUTOMOBILE Communication Cable DO NOT RUN CABLES IN EXIT PATH OF AUTOMOBILE Communication Cable Fig 3 Fig 4 Fig 2 NOTE Ensure Communication Cables are clear of fork...

Страница 7: ...that the System Configuration Lock Unlock light is green press the Raise Button to raise lifts off the locks B Press the Lower Button to lower lift The Slow Lower Button 1 3 speed can be used if desi...

Страница 8: ...column with an error Operating Instruction Details Options Changing the System Configuration Columns may only be added to or removed from a system by unlocking the existing configuration and then con...

Страница 9: ...ORKING IN THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES CONTAIN SULFURIC ACID AND PRODUCE EXPLOSIVE GASES A BATTERY EXPLOSION COULD RESULT IN LOSS OF EYESIGHT OR SERIOUS BURNS FOR THIS RE...

Страница 10: ...1 Lower lift check oil level in oil tanks on each column Open Power Unit Cover Remove oil cap and check oil level It should just be touching the dipstick If necessary fill with ISOVG32 hydraulic oil...

Страница 11: ...nger be guaranteed Follow manual lowering procedures E7 Short circuit detected A short has been detected in the lift actuators Press x to clear To determine the faulty component run the faulty column...

Страница 12: ...nect switch is OFF if one is provided on the lift 3 The authorized lockout person operates the main energy isolation device removing power to the subject lift If this is a lockable device the authoriz...

Страница 13: ...nal See Supplemental Diagram String NP932 Rev A AC in 230 V 2 2A 1 50Hz Battery Charger RS485 Comm Pot Contactors Red Black Black Red White Blue Black 1 White Black 2 Red Red Black Red Black Black Red...

Страница 14: ...14 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 15: ...15 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 16: ...e to lift owner operator Thank You Trained Operators and Regular Maintenance Ensures Satisfactory Performance of Your Rotary Lift Contact Your Nearest Authorized Rotary Parts Distributor for Genuine R...

Отзывы: