Installation
AYC-Qx4 Family Installation and Programming Manual
15
•
The individual wires extending from the reader are color-coded
according to the required Wiegand standard.
•
When using a separate power supply for the reader, this supply and
the controller’s power supply must have a common ground. A linear
power supply is recommended.
•
Attach the cable shield wire on the reader to an earth ground (best),
or to a signal ground connection at the panel or power supply end of
the cable. This configuration is best for shielding the reader cable
from external interference.
3.2.2
Wiring the Unit as a Controller
If you connect the unit to a Rosslare PS-x25x secured power supply, it
automatically functions as a controller.
To connect the unit as a controller:
1.
Select the appropriate connections according to Table 2.
Table 2: Wiring the Unit as a Controller
Controller Wire Color Function
Note
+
Red
+DC Input
Wired to the PS-x25x
-
Black
Ground
Wired to the PS-x25x
C 1
White
Communication
Wired to the PS-x25x
C 2
Green
Communication
Wired to the PS-x25x
AUX. IN
Brown
Auxiliary Input
Wired to input
N/A
Purple
Not in use
N/A
Attach the cable shield wire on the unit to an earth ground (best).
You can also attach it to a signal ground connection at the panel or
power supply end of the cable. This configuration is best for
shielding the controller cable from external interference.
2.
Prepare the PS-x25x secured power supply’s cable by cutting the
cable jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm (½”).
3.
Splice the controller pigtail wires to the corresponding PS-x25x
secured power supply’s wires and cover each joint with insulating
tape.
4.