Controller Operation
AYC-F/Gx4 Series Installation and Programming Manual
47
5.9.9.8
Auxiliary Mode 7
Auxiliary input function:
Door Monitor
Auxiliary output activated by:
Door Ajar (door held open)
For example, in Auxiliary Mode 7, the controller can trigger the
auxiliary relay, if it detects that the door has been held open (ajar) too
long. In this mode the auxiliary input functions as a door monitor
switch and is wired to the magnetic contact switch on the door. The
auxiliary relay is to be wired to the alarm system. If the door is
opened, the controller waits for the door ajar delay time to elapse and
if the door does not close prior to the end of this period, the
controller activates the auxiliary relay. The auxiliary setting defines the
door-ajar time.
5.9.9.9
Auxiliary Mode 8
This mode controls the door indicator (right LED).
The right LED is not lit when:
•
A valid code is entered
•
While in Secure mode when waiting for Secondary code.
Auxiliary input function:
Green LED control
Auxiliary output activated by:
Valid user code, Auxiliary code
For example, in Auxiliary Mode 8, the controller can function as a
2-door controller and also provide LED indicator functionality control.
The auxiliary relay is connected to the lock on the second door. The
auxiliary setting defines the Door Open time for the second door. The
auxiliary input is used to control the door indicator (right LED). If the
auxiliary input is open, the right LED flashes green; if the auxiliary
input is closed, the right LED flashes red.