![Rosslare AYC-F Series Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/rosslare/ayc-f-series/ayc-f-series_installation-and-programming-manual_1489264052.webp)
Controller Operation
52
AYC-F/Gx4 Series Installation and Programming Manual
The right LED turns orange.
3.
Enter
000
as the 3-digit user slot number.
The right LED flashes orange.
4.
Perform one of the following:
Enter the 4- to 8-digit PIN code
belonging to the user for whom you wish
to add a Secondary code.
Present the user card belonging to the user for whom you
wish to add a Secondary code.
The left LED flashes red.
If the Primary code entered is not valid, you hear a long beep and
the unit continues to wait for a valid Primary code.
5.
Perform one of the following:
Enter the 4- to 8-digit code to be used as
the Secondary code.
Present the user card to be used as the Secondary code.
If the Secondary code is valid, the controller beeps three times
and returns to Normal mode.
If the Secondary code is invalid, the controller sounds a long
beep, and the unit continues to wait for a valid Secondary code
to be entered.
Red
Orange
Orange
Orange