![Rosslare AC-F Series Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/rosslare/ac-f-series/ac-f-series_installation-and-programming-manual_1489252064.webp)
Programming
AC-F/G4x Series Installation and Programming Manual
63
4.
Do one of the following:
Enter the PIN code of the Primary code
belonging to the user you want to
delete.
Present the user card of the Primary code belonging to
the user you want to delete.
The left LED flashes green.
5.
Enter the assignment digit for the current user slot:
1
activates the Lock Strike relay only default
2
activates the Auxiliary relay only
3
activates the Lock Strike and Auxiliary relays
If the assignment digit is
valid, three beeps are heard and
the controller returns to Normal mode.
If the assignment digit is
invalid, a long beep sounds and the
controller waits for another assignment digit to be entered.
Green
Orange
Содержание AC-F Series
Страница 71: ...0706 0960101 04 CERT ISO 9001 ISO 14001 ...