Operation
24
AC-F/G4x Series Installation and Programming Manual
green for 10 seconds, during which the Secondary code must be
entered. A Master user only needs to present the code once to
gain entry.
4.1.3
Bypass Mode
The left LED is orange.
In Bypass mode, access to the premises is dependent on whether
the controller's Lock Strike Relay is programmed for Fail Safe
Operation or Fail Secure Operation. When the Lock Strike is
programmed for Fail Secure Operation, the door is locked until
*
is pressed. When the Lock Strike is programmed for Fail Safe
Operation, the door is constantly unlocked.
4.2
User Levels
The AC-F4x and AC-G4x series access control units accept up to
500 users and provide entry via the use of codes. Each user is
allocated two memory slots: Memory Slot 1 (Primary code) and
Memory Slot 2 (Secondary code).
The way in which the two memory slots are programmed,
determines a user’s access level and also establishes access is
granted for each of the three modes of operation. There are
three user levels:
Normal
Orange