Voyager Maintenance Guide (v02)
Hard Drive Maintenance • 4–3
RAID Array Consistency Check
It is important to check the Voyager RAID array for consistency. Consistency checks ensure that all drives are
functioning and that damaged sections are repaired. It is recommended that consistency checks are performed on a
weekly basis.
Consistency checks can affect the performance of the Voyager server. Consistency checks should only be
performed or scheduled when Voyager is not in use.
To run a consistency check on the Voyager RAID array:
1.
Open the
MegaRAID Storage Manager
.
2.
In the
MegaRAID Storage Manager
, from the menu bar, select
Manage
>
Check Consistency
.
The
Group Consistency Check
dialog box opens.
Figure 4.4
Storage Manager - Group Consistency Check
3.
From the
Select Virtual Disks
section, select the check boxes of the virtual drives to check for consistency, or
click the
Select All
button to select all of the virtual drives.
4.
Click
Start
.
The consistency check starts.
For More Information on...
• opening the MegaRAID storage manager, refer to the procedure
Содержание YOYAGER X1