SEA-8803 User Manual (Iss. 02)
Installation • 2–5
Cabling
The SEA-8803 can operate as a single 1x8, or as a single 1x4 depending on the rear module you
are using. This section provides cabling details for supported configurations.
Single 1x8 Configuration
The 8320AR-300 Full Rear Module is used when operating as a single 1x8 configuration. Each
rear module occupies two slots and accommodates one card. This rear module provides an SDI
input, and eight SDI outputs via BNC connections. (
Figure 2.2
)
Figure 2.2
Cable Connections for the 8320AR-300 Full Rear Module
Single 1x8 Configuration with Bypass Relay
The 8320AR-306 Full Rear Module is required when operating as a single 1x8 configuration with
a bypass relay. Each rear module occupies two slots, and accommodates one card. This rear
module provides one SDI input, and eight SDI outputs via BNC connections. A bypass relay
between SDI IN and OUT 1 is also provided. (
Figure 2.3
)
Figure 2.3
Cable Connections for 8320AR-306 Full Rear Module
Important
— It is necessary to terminate unused outputs.
1 2
3 4
5 6
7 8
9 10
SDI IN
OUT 1
OUT 3
OUT 5
OUT 7
N/C
OUT 2
OUT 4
OUT 6
OUT 8
Card 1
Card 2
1 2
3 4
5 6
7 8
9 10
N/C
OUT 5
OUT 6
OUT 7
OUT 8
SDI IN
OUT 1
OUT 2
OUT 3
OUT 4
CF