RCP-QE User Guide (v02)
Setting Up the RCP-QE • 4–27
The Button configuration box opens.
3.
In the
Button
list, select
Salvo
.
4.
Use the
Value
list to select one of the Salvo names.
5.
Send the current configuration file to the device as outlined in the section “
Sending a Configuration File to a
Assigning a Category Index Mode Button
This function is only available when connected to an Ultrix series router or Ultricore Central Controller.
Category Index mode allows the grouping of sources and destinations in a hierarchical tree structure similar to the
'breadcrumb' user interface pattern found on many websites. Category Index also allows for numerical label
extension selection for multiple labels having the same prefix. The assignment of sources and destinations is
defined within a central controlling device (Ultrix router or Ultricore Central Controller).
To assign a Category Index mode button:
1.
Open the RCP-QE Panel Configuration editor as outlined in the section “
2.
On the simulated RCP-QE, select the button that you want to use for the display.
The Button configuration box opens.
3.
In the
Button
list, select
Category Mode
.
4.
Send the current configuration file to the device as outlined in the section “
Sending a Configuration File to a
Clearing a Function from a Button
If a button is not used for any function it should be unassigned.
To clear a function from a button:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
On the simulated RCP-QE, select the button from which you want to clear a function.
The
Button
configuration box opens.
3.
In the
Button
list, select
Clear Key
.
4.
Close the
Button
configuration box.
The simulated RCP-QE in DashBoard blackens the selected button.
5.
Send the current configuration file to the device (see “
Sending a Configuration File to a Device
Locking an RCP-QE
You can use DashBoard to lock access to the front of a remote control panel. The remote control panel can only be
unlocked locally if you have assigned a panel lock or protect button. If these buttons have not been assigned, then
the remote control panel may only be unlocked via DashBoard.
To lock the RCP-QE:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
Select the
Configuration
tab.
Содержание NK Routing Systems RCP-QE
Страница 1: ...RCP QE User Guide Version 02 ...
Страница 10: ...1 2 Introduction RCP QE User Guide 02 ...
Страница 14: ...2 4 RCP QE Overview RCP QE User Guide v02 ...
Страница 20: ...3 6 Installation RCP QE User Guide v02 ...
Страница 66: ...6 2 Troubleshooting RCP QE User Guide v02 ...
Страница 68: ...7 2 RCP QE Hexadecimal to Router Level Conversion RCP QE User Guide v02 ...