Ross HDBH Series Скачать руководство пользователя страница 2

   HDBH Series Operating Instructions  

2

       

 

www.rosscontrols.com

SCHEMATIC

WIRING DIAGRAM 

Inductive Position Switch

 Connector

A

A B

B

A

A B

B

G

G

a

a

1A

1B

P

P

A

A

B

B

T

T

Valve Side

Manifold Side

1 = 24 volts DC

2 = Output Signal NC

3 = Ground

4 = Output Signal NO 

NO NC

1

4

3

2

PRODUCT LABEL IDENTIFICATION

OVERALL DIMENSIONS

 

    

MODEL NUMBER

ISO Size

Monitoring 

Weight  

lb (kg)

HDBHDC3BAEXA

06 (D03)

External

15.0 (6.80)

4.5 (115)

5.5 (140)

10.0 (255)

5.03 (127.8)

3.9 (100)

3.4 (87)

 

2.23 (56.7)

 

2.06 (52.4)

Inductive Position 

Switch Connector

Solenoid 

Connector

Bracket 

Connection Bar

Tamper-resistant 

Bracket

Dimensions –

 inches (mm)

2.25 (57.2)

1.75 (44.5)

0.13 (3.2)

0.13 (3.2)

0.75  (19.1)

2.25 (57.2)

1.13 

(28.6)

2.25 (57.2)

1.75 (44.5)

0.47 (11.9)

 (4X) Ø 0.219 (5.6) Thru

 

Spacer Kit 

0.75 inches (19.1 mm)

Spacer Kit  

1.75 inches (44.5 mm)

Spacer Kits

Kit Type

Height  

inches (mm)

Model Number

Ductile

0.75 (19.1)

2548B25  

1.75 (44.5)

2549B25

Spacer kits can be used to raise the HDBH system higher above the manifold surface 
in order to avoid interference with other devices on the manifold.  Kits are either 0.75” 
or 1.75” tall.  Combine kits as necessary to achieve the desired spacing.

1A

1B

P

P

A

A

B

B

T

T

G

G

B

B

A

T

A

T

A

T

B

A

B

T

X

X

X

X

X

X
X

X

X

4.0 (101.6)

7.9 (201.67)

2.0 

(50.8)

2.0 

(50.8)

In-line Mounting Kit

Kit Number

2790B77

In applications where installation on a manifold is not practical, the in-line mounting kit can be used 
to facilitate installation in-line between a directional valve and actuator (typically a cylinder).  The 
2790B77 kit provides 2 mounting plates with multiple SAE 06 ports for the A, B, and T ports in order 

to provide for flexibility in piping.  At least one of the T ports must be piped back to the tank.  Through 

holes (0.422” dia.) for mounting the assembly are included in the plates.  All assembly hardware 
and plugs are included, but mounting hardware for the assembly must be provided by the customer.

Dimensions –

 inches (mm)

Dimensions –

 inches (mm)

Содержание HDBH Series

Страница 1: ...HDBH Series Redundant Safety Valve System Hydraulic Dual Block Stop Operating Instructions www rosscontrols com RC HDBH OI EN Cat 4 PL e SIL 3 Functional Safety Pending Pending...

Страница 2: ...2548B25 1 75 44 5 2549B25 Spacer kits can be used to raise the HDBH system higher above the manifold surface in order to avoid interference with other devices on the manifold Kits are either 0 75 or 1...

Страница 3: ...uid Certain solvents and aggressive cleaning agents or detergents may damage the seals on the HDBH valve and make them age faster Never use solvents or aggressive detergents as these can cause damage...

Страница 4: ...above maximum operating pressure 6 2 Responsibilities of the System Owner Observation of general requirements pertaining to hazards Unusual noises vibration defects or damage is to be remedied immedi...

Страница 5: ...linders or other actuators or even other valves in the circuit may cause unexpected movement In order to test for leakage within the HDBH itself it is necessary to check for actuator cylinder movement...

Страница 6: ...gic PNP 1 supply 24 V DC 4 NO output signal 2 NC output signal 3 GND OUTPUT SIGNAL STATUS FOR EACH VALVE IN THE HDBH SYSTEM Hydraulic configuration ON OFF ON OFF Spool position Pin 2 Pin 4 S Note PNP...

Страница 7: ...HDBH Series Operating Instructions www rosscontrols com 7...

Страница 8: ...5 sales rossfrance com www rossfrance com Asia Pacific Japan ROSS ASIA K K 81 42 778 7251 custsvc ra rosscontrols com www rossasia co jp India ROSS CONTROLS INDIA Pvt Ltd 91 44 2624 9040 sales ri ross...

Отзывы: